The most effective way to extinguish a combustible metal fire is with the use of a class___
Extinguisher because it absorbs heat and smothers the flames cutting off oxygen

A

D

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The Fdny currently has how many class D extinguishers?

A

Two they have slightly different capabilities available for use. They are the met lx and the lith X

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Met l x handheld extinguisher can be identified by the___ label affixed to the extinguisher which states Met l x for class d fires only

A

Yellow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The ___ Extinguishers are superior I’m very hot burning metal fire such as lithium

A

Lith x

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

______ extinguisher is superior to adhering to hot vertical surfaces

A

Met l x. Lith x effectiveness on vertical surfaces is diminished. Lith x does not adhere to metal surfaces so it is necessary to cover the burning metal completely

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Lith x handheld extinguisher can be identified by the label affixed to the extinguisher which states lith x. Will lith x extinguishers have a yellow identification label as found on the met l x?

A

No yellow label on the lith x

meth turns teeth yellow. Adheres you’re metal better

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Optimum distance to start extinguishment is approximately___ From the burning material which is well within the range of these extinguishers

A

10 ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Discharge time approximately___. Coverage up to ___square feet at a ___thickness

A

30 seconds.

3 sq ft at a 1” thickness

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

T/F

Temperature restrictions are -40 to 120°F

A

T

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

T/F

The extinguishers to be maintained up right

A

T

The extinguisher will not function properly if it is held in a horizontal or inverted position while being used

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What should be held by the member strongest hand?

A

The nozzle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Direct the powder at the___

A

Base of the material burning.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

It is important that overhaul of the hazard is delayed until the fuel has cooled. This may take up to___

A

30 mins

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

One met l x and one lith x Handheld extinguishers have an issue to the following units;

A
Haz Mat
Rescue
Hmtu’s
Squad
Soc support ladders
Purple k units
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The met ld and the lith x Shall be inspected when?

A

Weekly and after each use.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Inspection shall include:

A

Ensure the extinguisher is in its designated place and there’s accessible for immediate use.
Examine the CO2 cartridge to ensure it has not been punctured
Any signs of physical damage, corrosion or other impairments.
Examine hose to ensure it is intact

17
Q

Anytime though met mx or lith x
Extinguishers have been use that an incident or a defect is discovered during inspection, the company officer shall attach an RT to and forward it to?

A

Hazmat operations for replacement. Field unit shall not refill expanded extinguishers