Test Questions Part 2 Flashcards
_____________ are used to connect pipes of the same diameter, creating a straight run of pipe.
Nipples
Couplings
Bushings
Elbows
Couplings
The _______ fan blows combustion air into the wind box of a boiler.
Induced draft
High pressure
Balanced draft
Forced draft
Forced draft
As compared to a cooler water sample, warmer water:
is more dense
cannot hold as much dissolved oxygen
has a lower vapour pressure
is not considered a major pollutant
cannot hold as much dissolved oxygen
Combustion of fuel in a boiler furnace:
Requires a higher air-fuel ratio than a diesel engine
Should occur with a minimum of excess air
Is perfect when the stack gases are free of moisture
Requires mechanical draft
Should occur with a minimum of excess air
A _____ is a water filled section, which surrounds the firebox in a locomotive boiler.
Crown sheet
Boiler drum
Steam dome
Water leg
Water leg
The balanced equation for the incomplete combustion of carbon is:
C + O2 = CO2 + heat
2C + O2 = CO + heat
C + 2O2 = 2CO + heat
2C + O2 = 2CO + heat
2C + O2 = 2CO + heat
Synchronous motors have construction that is identical to:
DC series motors
DC shunt motors
AC induction motors
Alternators
Alternators
One of the advantages of the refractory (gas) burner is:
The air and gas mixture is thoroughly preheated before it enters the furnace
The flue gases are re-circulated back to the furnace to increase the furnace temperature
The flue gases are thoroughly post-heated before it leaves the furnace
The flame is directed to areas where it is needed the most
The air and gas mixture is thoroughly preheated before it enters the furnace
Limestone, when added to a fluidized bed boiler
Lowers the combustion bed temperature
Acts as a de-sulphuring agent
Absorbs NOx
Reduces greenhouse gas emissions
Acts as a de-sulphuring agent
Combustion air for the burners is preheated in the _____ by hot flue gases.
Economizer
Air heater
Superheater
Windbox
Air heater
When working with high voltages the following precautions should be observed:
access should be locked, allowing only authorized personnel to enter
remove all grounding straps before proceeding with the work
only allow workers from the utility to work on the equipment
make sure the voltages are safe before contacting live conductors
access should be locked, allowing only authorized personnel to enter
Which of the following is NOT necessary for complete combustion of a fuel?
The temperature of the furnace must be high enough
The combustion air must be preheated
Enough time must be allowed for the fuel to burn
The air and fuel must mix thoroughly
The combustion air must be preheated
Which of these is not a steam drum internal component?
Chemical feed pipe
Chevron dryer
Baffle
Intermittent blow off line
Intermittent blow off line
Utility companies have a surcharge to their customers based on:
The maximum amperage used
System capacitance
Transformer efficiency
Peak power demand
Peak power demand
An intermittent pilot:
Lights the main flame then extinguishes
Must be manually ignited
Lights the main flame and remains on until the main flame is extinguished
Remains on after the main flame extinguishes
Lights the main flame and remains on until the main flame is extinguished