Test Instruments for Coating Concrete Flashcards
What is ASTM D 4263?
Standard Test Method for Indicating Moisture in Concrete by the Plastic Sheet Method
What is ASTM F 1869?
Calcium Chloride Test
What is ASTM F2170-02?
Standard Test Method for Determining Relative Humidity in Concrete Floor Slabs Using in Situ Probes
What is ASTM D 7682-10?
Standard Test Method for Replication and Measurement of Concrete Surface Profiles using Replica Putty
Describe the test procedure for the plastic sheet method
• 0.1 mm (4.0 mil) thick, clear polyethylene sheet approximately 457 x 457 mm (18 x 18 in.)
• Taped over the concrete tightly sealed from the atmosphere and sunlight
• Remain a minimum of 16 hours
Describe the Calcium Chloride Test Procedure (ASTM F 1869)
• Weighed amount of calcium chloride
• Very hygroscopic, allowed to remain for an agreed period of time
• At the end of this period, the calcium chloride is removed and weighed again
What is the only product currently able to provide a permanent record of anchor profile of concrete/steel surfaces
The Concrete Profiler (TCP)
What is ASTM D6132?
Standard Test Method for Nondestructive Measurement of Dry Film Thickness of Applied Coatings Over Concrete Using an Ultrasonic Gage
What is SSPC-PA 9?
Measurement of Dry Coating Thickness Using Ultrasonic Gage
What is the preferred holiday tester for coatings over concrete?
High Voltage DC Constant Current
What standards are most commonly used for the determination of dry film thickness (DFT) of coatings on concrete by ultrasonic gauges? (Select all that apply.)
A. ASTM D6132
B. SSPC PA 2
C. SSPC PA 9
D. ASTM F186
A. ASTM D6132
C. SSPC PA 9
Which of the following materials are likely to be used to check moisture content in concrete?
A. Plastic Sheet
B. Potassium Ferricyanide
C. Calcium Sulfate
D. Replica putty
A. Plastic Sheet
Holiday Detection of fusion bonded epoxy, having a DFT of less than 500 microns (20 mils) is most commonly performed using
_________?
A. Low voltage DC holiday detection
B. High voltage AC holiday detection
C. Visual inspection is all that is required on FBE
D. High voltage DC holiday detection
D. High voltage DC holiday detection
High voltage on FBE