Describe the handheld Tachometer
Pocket Tach 99 from Monarch. Used for AFW STs and Emergency Bearing Oil pump PMs
Operating range-36”
5-99,999 rpm
Uses reflective tape on shaft and LED on unit
Describe the Digital Flow Meter and Display
Kessler-Ellis BAT R/T
Used for various Section 11 valve and check valve tests in the SI and AFW systems
- Once wired, operation is automatic
- totalizer updates every 2 seconds
- when an error occurs the display will flash
- batteries should be replaced one at a time to avoid interrupting the power
Must be plugged in when not in use.
Describe the Thermocouple meter
Used for ADV in service testing
- Fluke 51
- display reads - - - - when a thermocouple is not connected
- display shows OL (overload) when temp being measured is outside thermocouple’s valid range
- thermocouple types have color codes
- inspect casing before use, pay particular attention to insulation around connectors. Disconnect before opening case. Ensure polarity is correct. Don’t use around explosive gas, vapor or dust
Measures temperature
Describe the Portable Gas Analyzer
Eone Portable Gas analyzer
-Used during purging operations of main generator
Uses thermal conductivity
- minimize time analyzer is energized without flow to prevent overheating the sensor cell. Analyzer tubing should be hooked up to supply flow before unit is energized
- conducts 20 second self test when started
Describe the Heise PTE-1
Used for Containment Spray Pumps and Check Valves inservice ST
- uses different pressure modules.
- to change pressure modules, the unit must be off to prevent damage
- ensure you Zero out the reading. Do not ZERO out an absolute pressure module.
Describe the Wall 392MF Digital Heat Prober Thermometer
Used to measure the room temperatures in the AB when less than 2 supply and 2 exhaust fans are running
- -60 - 752 F