Taxpayers Flashcards

0
Q

1968 code states that a taxpayer must have automatic sprinkler system for area exceeding ?

A

7500 square feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

According to 1938 code a taxpayer must have sprinkler protection for an area over how many square feet?

A

10,000 square feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

2008 code states a group m-mercantile must have a sprinkler for taxpayers that ?

A

Full building-
1.area exceeding 12,000 square feet
2.or combined area on all floors including mezz exceeds 24,000
3. Storage area is high- piled racks or rack storage arrays
OCCUPANCY WITHIN BUILDING:
1. Area exceeding 7500 square feet or
2. Area of any size is located 3 stories above grade or
3.area of any size located in high rise building 4.or area of any size contains an Unenclosed stair or escalator connecting to or more floors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The cockloft in a taxpayer can be how high?

A

Can vary in height from 4 inches to more than 6 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

If on the roof of a taxpayer and want to find out if s protrusion on the roof is a division wall how would you find if it is a dividing wall

A

Strike with tool

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Concrete walls in taxpayers when subject to lateral load will fall in what manner ?

A

They sometimes hinge at ground level and entire side or rear wall will remain intact and fall out flat

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Brick walls if subject to lateral load will?

A

Crumble or break as they fall but large sections can bd projected a great distance due to impact

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

At what temperature do I beams begin start to soften and fail ?

A

1000 f to 1500 f

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Cast iron are unpredictable and fail in average in

A

About 30 min

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Which is a considered more serious failure of a structural component in a taxpayer ? The Failure of a column or a beam

A

Column

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When cutting a hole In roof of taxpayer for vent purposes the hole should be?

A

8x8 where possible

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Immediate vent and cutting of a roof at taxpayer calls for how many saws and how many members

A

Two saws and four members

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

If a roof operation involves more than how many saws at a taxpayer a roof sector supervisor must supervise

A

One power saw

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

If an engine company is using fog pattern on ft-2 nozzle to vent area how far back from opening should they stand back

A

4-5 feet away while filling the width of the opening

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Notes: general tactics eng ops cellar fire taxpayers
Supply line to cellar sprinkler if building has( high priority ) after establishment of initial line

Stretching lines to cellar enough line must be flaked out charged and kinks removed before advancing down stairs
If interior stair especially if open and conditions permit first line must be stretched to this point
Flooring must be checked for heat as advancing line to stairs and door to cellar door must be checked before it opened
When line can be advanced down interior stair to cellar second line must be stretched to back this line up

A

Flood first floor with stang or TL AS last resort

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

When should you use a stang or tower ladder pipe to flood first floor of taxpayer

A

As a last resort

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What should first engine company due at a fire in cellar of taxpayer

A

Stretch first line into occupancy above fire to prevent vertical extension
If bld has sprinkler and staffing and conditions permit a second line to charge sprinkler system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Second engine company at a fire in the cellar of a taxpayer

A
  1. Assist first due with initial line
  2. Feed sprinkler if not done by first and conditions and manpower
  3. After sprinkler stretch Line to back up 1 st line
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Second line in taxpayer cellar fire may be used for the following ?

A
  1. Control first floor if first line has advanced into cellar
  2. Serve as BU or protection line for first engine
  3. Stretch into into cellar via interior or exterior entrance if first line has to control first floor
  4. Employ use of cellar pipes
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Who ensures that sprinkler system is charged at cellar fire in taxpayer

A

Third engine company

Notes
If second due assisting first due with stretch than third due operate as second due would

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Additional engine companies ( after 3 eng) may

  1. Cover additional stores
  2. Supply distributor or cellar pipes
  3. Reinforce lines in op
  4. Supply heavy caliber streams
  5. Stretch lines to roof
A

Fourth due and above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

When should tower ladder streams, multiversals ,and deck pipe streams be used at taxpayer ?

A

As a last resort when roof or interior ops are dangerous after personnel withdrawn

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

First engine at store fire in taxpayer

A

First line into involved store to protect life and extinguish fire
Building protected by sprinkler system if conditions and staffing permit supply second line to feed system

23
Q

Second engine at store fire in taxpayer

A
  1. Assist first engine with initial line
  2. Sprinkler system supply if not done
  3. Stretch line to back up first
24
Third due at store fire in taxpayer
Ensure sprinkler | Operated as ordered by IC
25
Who ensures thst sprinkler is supplied at store fire in taxpayer
Third due engine
26
First due eng at a cockloft fire in taxpayer
If fire has control of cockloft and exposure protection critical than: 1. Position eng to use deck pipe (in-line will give good position and room for TL) 2. Handling to most seriously exposed occupancy or building 3. Exposure not immediate problem First line to store under main body of fire NOTES: Seriously exposed depends on life hazard and location and. Severity of fire
27
Second line at cockloft fire that has control of cockloft and exposure protection critical
1. Assist first due with initial line | 2. Second line into another seriously exposed bld/occupancy and operate into cockloft to confine and extinguish fire
28
Third engine at cockloft fire
1. Ensure sprinkler system supplied | 2. Operate as per IC
29
When should ladder company suspect a cellar fire at a taxpayer
1. Smoke shows in many stores 2. High heat condition on first floor with no visible flame Notes: cellar must always be checked
30
When venting a cellar fire by cutting hole in first floor the vent whole must be over the main body of fire ?
May not always be practical for cellar fires NOTES : May have to cut near skylights Floors should not be cut until hose line in postion
31
If you send member into cellar to check utilities you must ?
Send two members equipped with masks
32
Who shuts utilities at cellar fire in taxpayer
First due FE team
33
Roof man at cellar fire in taxpayer will?
1. Place and raise portable to roof 2. After coordinating with ladder company officer inside the fire area to be vented provide necessary roof vent of scuttles and skylights 3. Monitor roof unless otherwise directed
34
OVM at cellar fire in taxpayer shall
1. Check rear and sides of building for access 2. After communicating with officer inside area to be vented provide vent at rear 3. If can attempt entry in rear with 2nd OVM notify officer and search
35
First due TL LCC at cellar taxpayer fire
Front of building NOTES : If taxpayer fronts on two streets and front is covered by TL Then other TL on the other street front Position to drive fire back to point of origin
36
First due aerial at cellar fire in taxpayer
Away from front of building | Join FE team
37
Second due FE entry team at cellar fire in taxpayer
Adjacent stores and cellar entrances Search stores Coordinate vent check for extension Cut floors when necessary
38
Second roof man at cellar fire in taxpayer
2nd portable to roof Saw to roof if not required elsewhere Not required on roof perform as directed
39
Second OVM at cellar fire in taxpayer
Team up with first due OVM in rear
40
Second due LCC at cellar fire in taxpayer
Position TL for most effective utilization If aerial away from building Join FE TEAM
41
When should the show window in front be removed for ventilation purposes at a store fire in a taxpayer
When ordered by IC
42
The practicality of trenching will depend on
Size of roof Volume of fire Ceilings - height and type
43
At a store or cellar fire when should you remove the show windows for vent
When authorized by IC and when charged line in position
44
Who checks cellar for fire at a store or cockloft fire in taxpayer
First due FE team
45
Who shuts the gas and electric at a store or cockloft fire in taxpayer
First due FE team
46
First due roof at store or cockloft fire in taxpayer
Portable to roof Saw to roof ( saw may be required for FE ) Monitor roof and report changing conditions to IC
47
First due OVM at cockloft or store fire in taxpayer
Check rear for access Vent rear after coordination with ladder officer in area to be vented Enter and search rear with second OVM
48
LCC of aerial at store or cockloft fire should position aerial away from immediate building and leave access for TL then he should
Join FE team | Fire extend to cockloft go to roof to assist roof FF
49
Second due roof at store or cockloft fire in taxpayer
2nd portable to roof | Saw to roof assist with roof vent
50
Second due OVM at store or cockloft fire in a taxpayer
Team up with first due OVM | Proceed to roof or other position as directed
51
Second due LCC at store/cockloft fire in taxpayer
Position TL Rearmount place away Join FE team if not directed otherwise
52
Who should report in with their 10 and 12 foot hooks besides their normal compliment of tools
All trucks other than first and second arriving
53
What tool should OVM take to rear on taxpayer
Maul and Halligen
54
When using a power saw to remove the metal slats of security doors the saw makes two cuts to form a triangle the apex of the triangle
Apex at top