Accurate determination of material finer than No. 200 sieve can be achieved by use of this method?
False
For acceptance testing, the sample shall be dried to a constant mass in an oven according to ________.
T 255
For control purposes only, it is generally not necessary to dry coarse aggregate for the sieve analysis, provided that:
The nominal max size is about 1/2 in. or larger, The coarse aggregate does not contain appreciable material finer than No. 4, The coarse aggregate is not highly absorptive (such as light weight agg)
For sieves with openings smaller than No.4, the quantity retained on any sieve at the completion of the sieving operation shall not exceed _______ g/in^2.
4 g/in^2
For aggregates with a NMAS of 1/2” or less, use the same sample for testing by Aashto T 11 and this method.
True
The minimum dry mass for a 3/4” NMAS agg. is ______ kg
5
To determine if adequate sieving has been achieved, strike the side at a rate of about _________ strokes per minute, turning the sieve about one sixth of a revolution at intervals of about_________ strokes.
150, 25.