SWA B737 - Fire Protection Flashcards

1
Q

(Fire Protection) What would cause the FAULT light to illuminate on the Fire Detection/Protection panel?

A

Both loops to have failed.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

(Fire Protection) What electrical power must be available for the APU and engine extinguishing systems to function?

A

Electrical power is from the Hot Battery Bus.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

(Fire Protection) Where is there fire detection and extinguishing systems?

A
  • Engines (1 and 2)
  • APU
  • Cargo Compartments (Fwd. and Aft)
  • Lavatories
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

(Fire Protection) What does the APU DET INOP light on the Fire Detection/Protection panel indicate?

A

That the APU fire detection system is INOP.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

(Fire Protection) Where is there fire detection, but no extinguishing?

A

Wheel Well

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

(Fire Protection) With the OVHT DET switch in normal, is there an indication in the flight deck yhat a single loop failed?

A

No, it can only be discovered during the OVHT/FIRE test.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly