Steel Decking Flashcards

1
Q

A standard roof deck is installed to end lap approximately ___ inches over supports

A

2”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is Cellular Metal Deck?

A

Normal metal decking that has a flat piece of steel welded to the bottom of the panel.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is a “B” Deck Profile?

A

36” coverage with 1-1/2” x 6” Wide Rib (WR)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is a “F” Deck Profile?

A

36” or 30” coverage with 1-1/2” x 6” Intermediate Rib (IR)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the packaging deck bundle weight limit to be applied to joists?

A

4,000lbs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

For decking, what is a safe working platform size?

A

12 feet wide

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the minimum uniform construction live load for a floor deck?

A

20psf

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

If heavier motorized fishing equipment such as a power screed is needed for the deck, the uniform live load should be ___ or greater.

A

50psf

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Where should the end lap of decking be located? And what is the minimum length of end bearing that should be provided?

A

The end lap location should be adjusted so the center of the lapped portion occurs over the support/top chord member. The minimum length should be 1-1/2”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What are the typical screw size for decking?

A

12s or 1/4” diameter with a special drill point.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

When are weld washers nor recommended for deck thicknesses of what gauge or thickness?

A

0.028 inches thick
22 gauge

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What plate thickness is required for covering a dent or an 8” maximum hole diameter in decking?

A

0.045 plate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

For dents or holes greater than a rib (over 8” to 13” diameter or width), it is advisable to use a_____ minimum plate.

A

0.057”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

When aligning the edge of steel deck, the installer should____

A

kneel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

A roof steel deck with an opening of 6” long will require reinforcement when ___ webs have been removed.

A

Three

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

The connector, that is used to mechanically lock concrete and steel together to carry a floor load, is referred to as a _____ .

A

Shear Lug

17
Q

An extra heavy duty non-composite form deck with a nominal depth of 1-5/16” has a weight range of _____

A

1psf to 2.8 psf

18
Q

A good working weld develops its strength by holding _____.

A

Around the perimeter.

19
Q

Steel decks are usually less than ____ feet long.

A

40

20
Q

In order to reduce the possibility of the deck side opening, concrete should be placed in a direction so that the weight is first applied to the _______.

A

Top sheet at the side lap.