SSDG Flashcards
SSDG
Provides electrical power throughout the cutter
SSDG Description
Two 60 kW for 450 V three phase 60 Hz four-cylinder call in-line liquid cooled four stroke engines each design to run alone or in continuous parallel operations up to their combine maximum kilowatt raising
90 hp @1800 rpm
3.8 gallons L/O
4 gal of J/W
FO system provides
A means of supply and clean filtered fuel oil to the SSDG fuel injectors
What is the fuel oil differential pressure gauge
If the needle is to the right of zero it is red as pounds per square inch or psi if the needle is to the left of zero it is red as a vacuum inches of mercury
Do not exceed 10 inches
Where is the engine stop on the generator
On the generator panel
LO PRESSURE
Between 60 and 80 psi
Lube oil temperature parameters
No less than 130°F no more than 220°F
SSDG dipstick has to Marks what are they
Min and Max
What is the viscosity testing equipment for
This provides a measurement of the thickening of the lube oil within the low oil system
Engine cooling parameters for the SSDG
What is the normal jacket water temperature for the SSDG
Between 180 and 1 94°F maximum jacket water temperature 215°F
What is the jacket water level indicator provide
Do you want indication of the jacket water level within the expansion tank.
means for sounding an alarm when the jacket water level is low