slides Flashcards

1
Q

what are 5 Notifications to the ig

CCCMM

A

CRIMINAL, CONFLICTS OF INTEREST, MISCOUNDUCT AND MISMANAGEMENT

ANY ALLEGATIONS OF THEFTS BY EMPLOYEES

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

IMMEDIATE NOTIFICATION TO BITS SHOULD BE MADE WHEN?

LIST 6

A

ON DUTY POSSESSION OR USE OF DRUGS, (IF SELLING DRUGS =IG)

ARREST

PHYSICAL ALTERCATIONS

SERIOUS CONFONTATIONS WITH CIVILIONS

DANGEROUS MISUSE OF DEPT VEHICLES

ON DUTY CONFRENTONS BETWEEN MEMBERS OF PD OR OTHER GOV AGENCYS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

WRITTEN NOTIFICATION TO BITS

5

A

MISCONDUCT BY DEPT EMPLOYEE

FOLLOW UP ON ARREST

INCOMPETENCE SERIOUS ENOUGH FOR DISCIPLINARY CHARGES

PREFRENCE OF CHARGES

MISUSE OF DEPT TIME

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

WHAT IS THE ACCRONMYM FOR NOTIFICATION WHEN DOGS ATTACKING MEMBER?

PBA ME

A

POLICE

BOARD OF HEALTH

ACC

MEDICAL OFFICER

EMS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

WHAT IS THE ACRONYM FOR PET REMAINS AT FIRES?

PORN

A

PD’

OWNER

REPRESENTIVE OF BUILDING

NEIGHBOR

IF UNIFICATION NOT POSSIBLE CONTACT ACC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

UNITS ASSIGNED TO REMOVE WINDOW BARS MUST REMOVE AT LEAST?

A

ONE WINDOW ON THE FIRE FLOOR AND THE FLOOR ABOVE ARE CLEARED

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

WHAT IS THE MOST COMMON TYPE OF LW PEAKED ROOF?

A

OPEN WEB LW WOOD TRUSS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q
A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

HEAVY FIRE AND SMPKE ON A FLOOR BELOW WITH NO SMOKE ON FLOOR ABOVE IS INDICATION OF CONCRETE OR GYPSUM FLOOR POURED OVER CORRUGATED STEEL SUPPORTED BY ?

A

C JOISTS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

LW BUILDING NOT CONTAINED BY 2 HANDLINES OUTSIDE OPERATION MUST BE _____

A

CONSIDERED

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

LW PD NEVER CUT THE ROOF

WHEN FIRE HAS NOT ENTEREED COCKLOFT LIMITED ROOF OPS

WHEN FIRE IS IN THE COCKLOFT ____

NEVER OPERAGTION ON A CONTENT OR STRUCTUAL FIRE WITH A TRUSS

CAN ONLY OPERATE ON TRUSS IF NOT ON FIRE NEED IC APPROVAL

A

NO ROOF OPS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

WHAT IS THE MOST COMMON DECKING TAXPAYER OPEN WEB STEEL JOIST

HOW FAR APART ARE THE JOIST SPACED?

A

CORRUGATED STEEL

4-6 FEET

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

In refuse chutes constructed in new construction, sprinklers shall be provided spaced not more
than _____stories apart for the height of the chute.

They shall be recessed and so arranged that
fused sprinkler heads may be readily replaced unless __-____

A

2

electrically operated.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

IC shall special call CPC or HMTU as fast unity when how many entry CPC teams are expected to be put to work?

A

More than Two

The Incident Commander shall special call a CPC Unit or Haz-Mat Technician
Unit as a FAST unit to the scene if more than two entry teams are expected to be put to
work.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Whats the minimum number of victoms that must be encountered in cpc incident fo it to be multiple victim?

A

3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

gross decon ______ pressure streams ____volumes of water

A

low , High

17
Q

One option for setting up a mass Decon is to stretch a 21⁄2” handline equipped with
an Aquastream fog nozzle.

whats the psi?

A

-50-80