Sensor Quiz 2 Flashcards

1
Q

What is JCAD

A

Microbalance Based Detector

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What does JCAD detect

A

selective for specific functional group

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Interaction between CwA and polymer surface in JCAD

A

non-covalent
based on solubility

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What type of substance does JCAD test for

A

Vapours and liquids

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What does FTIR Spectroscopy detect

A

measure the amount fo light absorbed at a specific wavelngth

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

what does FTIR LOOK FOR

A

characteristics of chemical groups

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

True or false: The intensity of FTIR absorption is proportional to the concentration of the targeted chemical

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Sensitivity, LOD and detecition of FTIR

A

High sensitivity, low LOD and fast detection of vapours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

True or false: FTIR is destructive

A

FALSE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What kind of susbtance does THREATID device FTIR detect

A

Solid, liquid and gas mixture analysis

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

First defender device

A

warmup less and one second
takes 15 seconds
non-destructive
correctly identifies 78/88 CWAs
Failures in detection are below 10%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Gas phase detection of CWA with portable raman

A

~500 cm = bending of phosphate
~700 cm = stretching of PC
~800,830 cm = bending of phosphate 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

what is SERS spectrum

A

2.5ppmv

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the intesnsity value peak at of DMMP at exposure time 2.5ppmv

A

~700cm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

SERS Integrated Centrifugal microfluidic platform for detection facts

A

Concentration dependent intensity of charactereistic GA at 2100cm

Concentration dependent intensity of vx at 900cm
LOD is ~4.00ppm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

what is bioterrorism

A

involves deliberate release of bioweapons to cause death or disease

17
Q

What is Bioterrorism interpol

A

the spread of infectious or toxic biological agents can happen without warning

18
Q

What is biotracker

A

consists of an itelligence repository and visualization interface which member countries can feed and benefit from

19
Q

three biological agents for bioterrorism

A

anthrax - bacterial toxin
botulin - bacterial toxin
Ricin - plant toxin

20
Q

Methods of dissemination of toxins

A

air, food, water, soil

21
Q

Lab based methods of biological agents

A

Immunoassays
PCR assays
Animal assays

22
Q

On-site testing methods of bioogical agents

A

Colorimetric detection
Fluorescent detection
electro chemical detection

23
Q

What are device requirements

A

attract non-covalently

24
Q

How to find recognition probe on ricin

A

protein-protein
Protein-nucleic acids
antibodies-protein

25
Q

What is ricin sensor recognition probe

A

nucleic acid

26
Q

What is a bulge

A

Mad eof C nuclear base

27
Q

Where does probe attach to surface

A

Graphene surface

28
Q

How is the FAM molecule attached

A

covalently to the 5’ end

29
Q

Relationship of detection and fluorescence

A

increase in fluorescent dye, increase in signal

30
Q

Where is the dye quenched

A

near carbon surfaces

31
Q

A self-driven microfluidic chip in ricin detection paper facts

A

Measured fluorescence
Detection of AT and RT
Greater intensity of colour, higher the value
tested at 700nm
Bot, ETX, AT and PBS were negative,
Ricin was positive

32
Q

What was the botulin toxin colorimetric antibody based test measured in

A

ng/mL - measures absorbance
increase of concentration = increase of absorbance

33
Q

What is the most sensitive test

A

colorimetric

34
Q

Anthrax spore detection using antibodies describe the test

A

sample goes on detection pad
Conjugate pad is where binding occurs
Spores bind to antibody
Travel through the test line and control line
antibody binds to lines
If anthrax is in sample it will be captured by antibody and both lines are coloured

35
Q

Dipicolinic acid or DPA structure

A

Pridine, 2 carboxylic acids

36
Q

What is a major component of anthrax spores

A

DPA, 15% of dry mass

37
Q

Under UV lamp what colour does DPA positive

38
Q

What is the range DPA is measured in

A

micromolar