SCBA Flashcards
An approved SCBA CBRN regulator can be identified by what color background label?
1.2
An approved SCBA CBRN regulator can be identified by its orange background label. An approved back frame assembly can be identified by a CDC NIOSH sticker.
Members are not fully protected from CBRN agents unless wearing the NFPA 2007 compliant SCBA in conjunction with what 2 things?
1.3
Proper Protective Clothing (e.g., “Level A” entry suit) and proper Haz-Mat training.
What are the proper procedures if a member runs out of air in his SCBA?
2.1.7
If a member runs out of air, that member should remove the regulator from the facepiece. The donned facepiece will provide some protection to the skin on the face. Notify Officer and immediately leave the contaminated area. This member MUST be accompanied to a safe area by another member using an SCBA.
The Code of Federal Regulations 29-CFR 1910.146 defines a confined space as any area that is?
(3 answers)
- 2
- Not designed for continuous human occupancy; and
- Large enough so a person can enter and work; and
- Has limited means for entry and escape
Confined spaces include, but are not limited to, basements, sub-basements and cellars, manholes, pits, tunnels, wells, windowless buildings, storage containers, and other spaces that may be oxygen deficient or contain dangerous levels of airborne contaminants. All confined spaces are to be considered dangerous until proven otherwise. All members entering a confined space shall operate with SCBA donned until what?
2.2.3
All members entering a confined space shall operate with SCBA donned until the space is deemed safe.
Members operating in a confined space must work in teams of ___ or ____ and maintain contact with each other.
Fill in the blanks
2.2.4
Members operating in a confined space must work in teams of two or more and maintain contact with each other, in case assistance is needed.
Contact lenses may be worn with the SCBA. Corrective eye lenses can both be worn with the SCBA when what is issued to the member?
- 3.1 Contact lenses may be worn with the SCBA.
- 3.2 When the use of corrective eye lenses is required during SCBA use, the corrective lenses must not interfere with a good seal between face and facepiece. Glasses with temple bars or straps that pass between the face and the seal of the facepiece must not be used. Each size facepiece may be equipped with a lens frame kit. The Department will issue corrective lens kits to members that request them.
The SCBA is NEVER to be used underwater. Submersion in water will render the SCBA inoperative. What shall be done if the SCBA is submersed in water?
2.4.3
If the SCBA becomes submerged it MUST be placed out of service and returned with a completed service tag (RT-2) stating the problem to the Mask Service Unit.
The harness assembly consists of two adjustable shoulder straps and adjustable waist straps made of Kevlar with a quick release buckle. The shoulder straps have pockets through which the low pressure hose and the remote gauge line pass. Where is most of the weight of the SCBA distributed?
3.1.2
The waist belt rests on the hips of the wearer and distributes most of the weight of the SCBA to that area.
Pressurized to ____psi, the cylinder holds purified breathing air.
Fill in the blank
3.2.2
4500 psi
The Date of Manufacture is listed on the SCOTT label by month and year. The service life of an air cylinder is how many years?
3.2.3
The service life of an air cylinder is 15 years. If a manufacture date is greater than 15 years, the cylinder must be removed from service, bled down, tagged, and returned to MSU.
Hydrostatic testing of the SCBA cylinder is done every __ years.
Fill in the blank.
BONUS
What cylinder needs hydrostatic testing every 3 years?
3.2.4
Hydrostatic testing is done every 5 years. If the test date shows greater than 5 years, the cylinder must be removed from service, bled down, tagged and returned to MSU. The hydrostatic test date will also be found on the top of the cylinder. For example, the number 102 will indicate that this cylinder was tested in January of 2002, and will need to be retested by January of 2007.
A. 10 minute escape cylinders used by Special Operations Command (SOC) units for confined space, need to be hydrostatic tested every 3 years.
The End of Service Time Indicator (EOSTI) alarms (vibralert and HUD) actuate when approximately how many percent of full cylinder pressure remains in the cylinder and valve assembly?
2.8
The End of Service Time Indicator (EOSTI) alarms (vibralert and HUD) actuate when approximately 25% of full cylinder pressure remains in the
cylinder and valve assembly. The alarms will continue to operate until the cylinder is nearly depleted.
.
The working and exit time of the SCBA depends on many factors. one such factor is the atmospheric pressure; in a pressurized tunnel or caisson at 2 atmospheres, the duration will be ________ as long as when used at 1 atmosphere; and at 3 atmospheres, will be _________ as long.
Fill in the blanks
3.2.9
one half
one third
Depots, High-Rise Units, company and reserve apparatus spare cylinders shall be inspected for full pressure when?
3.2.12
Inspect all spare cylinders (depots, High-Rise Units, company and reserve apparatus) weekly on Mondays for FULL pressure (4500psi). Stored cylinders found below FULL should be tagged and returned to the Mask Service Unit for further inspection.
The high pressure hose and high pressure hand coupling conveys breathing air from the cylinder to the pressure reducer assembly. Air pressure within this hose can be as much as how many psi?
3.4.1
4500psi.
During inspection of the SCBA, there may be a need to tighten or replace the Nylon O-Ring. To do so, use a ___” Allen wrench and a ____” open end wrench.
3.4.2
Use a 1/8” Allen wrench and a 7/16” open end wrench.
General Knowledge
Universal Air Connection (UAC)
3.5.1
SCOTT 4.5 SCBAs are fitted with a UAC System which permits emergency replenishment of an approved SCBA breathing air supply cylinder on a user’s SCBA from an approved air supply source while in use. This is not a Quick Charge attachment and must not be used for routine recharging of the air cylinder, buddy breathing, transferring air from another SCBA, or any other unapproved use. The UAC is for emergency use only when the SCBA user is incapacitated within the hazardous atmosphere. The UAC manifold is equipped with a relief valve which will open if the supply pressure of the emergency air supply exceeds the maximum pressure rating of the complete SCBA. However,
the supply pressure from the High Pressure Coupling, of the emergency air supply to be connected to the UAC, must not exceed 4500psi.
The UAC Connection must have its protective dust cover in place. A missing cover allows damage to the UAC or debris and contaminates to enter the connection, facilitating a possible malfunction when used with an approved air supply source. An SCBA with a missing UAC dust cover shall be what?
3.5.2
An SCBA with a missing UAC dust cover shall be placed out of service. It must be tagged with an RT-2 and forwarded to MSU.
The Pressure Reducer Assembly (PRA), mounted on the left side of the backframe, reduces the high pressure breathing air received from the cylinder. Consisting of two systems, the PRA normally reduces the operating pressure to ___ psi before entering the regulator’s low pressure hose. The regulator then controls the pressure within the facepiece to?
Fill in the blank and answer the question
- 6.1
- 100 psi
- Slightly above atmospheric pressure.
A malfunction of the PRA’s primary system will automatically direct breathing air into a secondary system. When this occurs, the operating pressure will only be reduced to how many psi?
3.6.2
150 psi and cause the vibralert alarm to activate. The member will only know that the vibralert alarm has activated and must notify their officer and immediately leave the contaminated area. This member must be accompanied to a safe area by another member using a SCBA.
Failure of both the primary and secondary systems in the open position will activate a Relief Valve in the PRA, which will rapidly discharge all pressure in excess of ___ psi into the atmosphere.
3.6.3
185 psi into the atmosphere.
Failure of both the primary and secondary systems in the open position will activate a Relief Valve in the PRA, which will rapidly discharge all pressure in excess of 185 psi into the atmosphere. What must be done when this occurs?
3.6.3
When this occurs, the cylinder valve should be partially closed, allowing only a minimal amount of air to release, permitting the member to both breathe and conserve air. The member must notify their officer and immediately leave the contaminated area. This member must be
accompanied to a safe area by another member using a SCBA.
Positive Pressure Demand Regulator- Regulates and maintains pressure within the donned facepiece. This is done with the breathing air received from the Pressure Reducer Assembly. The positive pressure inside the facepiece (internal pressure) is slightly higher than what?
3.8.1
Than the pressure outside (atmospheric pressure)
A manual shut-off switch is mounted on top of the regulator assembly. The function of the switch is to stop the flow of air into the facepiece prior to facepiece removal. When used, the switch conserves the limited amount of breathing air which can remain in the SCBA. If the switch is
not pressed, a full 45 minute cylinder can be depleted in approximately how many minutes?
3.8.2 A
4 minutes, exhausting the member’s available breathing air.
The manual shut-off switch automatically releases when the member inhales sharply through the facepiece, allowing air to continue to flow. If the manual shut-off fails to release for any reason, turn the red purge valve ________, ___ degrees to start the flow of air. Notify the officer and leave to a safe area, accompanied by another member using a SCBA.
Fill in the blanks
3.8.2 B
downward,180 degrees
The vibralert is an End of Service Time Indicator (EOSTI) that activates at approximately how much % of the cylinders air capacity remaining?
3.8.5 B
The vibralert is an End of Service Time Indicator (EOSTI) that activates at approximately 25% of the cylinders air capacity, alerting the member to exit the contaminated area. The vibralert and HUD work independently and may not activate at precisely the same time.