RQC-Know Flashcards

1
Q

What are all the reactor trips with Coincidence and Setpoints?

A

SR High Flux, 1/2 @ 90,000 cps

IR High Flux, 1/2 @ 22.5% (20%) RTP

PR Hi Flux, Low SP, 2/4 @ 20% RTP

PR Hi Flux, Hi SP, 2/4 @ 107% RTP

PR Hi + Rate, 2/4 @ 4.5% in 2 sec

OP delta T, 2/4 variable

OT delta T, 2/4 variable

PRZ Press Hi, 2/4 @ 2385#

PRZ Press LO, 2/4 @ 1950#

PRZ Water Level Hi, 2/3 @ 92%

RCS Loss of Flow, 2/3 on 1/4 Loops > P8 or 2/3 on 2/4 Loops between P7 and P8 @ 91%

UV- RCP Busses, 1/2 on 2/4 busses @ 88 V

UF- RCP Busses, 1/2 on 2/4 busses @ 58.2 Hx

RCP Breaker Positions, 2/4 Open Aux Switch

SG Water Level LO LO, 2/3 on 1/4 SG @ 5% (22%)

SG Water Level Low w FF < SF, 1/2 on 1/4 SG and 1/2 on same SG @ 15% (26%) and 0.71E6 (1.47E6) lamp/hr

SI either Train

Turbine Trip, 2/3 oil press 800# or 4/4 SVs < 1%

Manual

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the RPS safety related Functions?

A

Keep fuel within DNBR and Limit RCS Pressure within design

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the RPS non-safety related functions?

A

Initiate turbine trip from Rx Trip and give status and alarm conditions

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What are the SI Signals with coincidences and Setpoints?

A

Manual

Containment Press Hi, 2/3 @ 1#

PRZ Press LO, 2/3 @ 1775#

DP by Steam Lines, 1 SG < 2 Others, 2/3 on any steam line @ 100 psig

SG Press LO, 1/1 on 2 SGs @ 500#

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What are the CTS signals with coincidences and setpoints?

A

Manual

Containment Press Hi Hi, 2/4 @ 2.8#

MUST ENERGIZE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What are the Steam Line Isolation signals with coincendences and setpoints?

A

Manual

Containment Pressure Hi Hi, 2/4 @ 2.8#

High Steam Flow w P-12, 1/2 on 2 SGs @ 1.42E6 (1.6E6) variable w power

SG Pressrue, 1/1 on 2 SGs @ 500#

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What are the Turbine Trip and FWI signals with setpoints and coincidences?

A

SG Level Hi Hi, 2/3 on 1 SG @ 67%

SI

Rx Trip (P-4) w LO Tavg, either trip breaker open

FWI ONLY, Tave < 554*F on 2/4 loops

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What does it take for P-4 to be active?

A

Both Rx Trip A or B and same Bypass Breaker open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the function of P-4?

A

With Low Tavg, gives FWI

Seals in FWI from SI or Hi Hi SG Level

Permits manual block of auto SI Signals

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What does it take for P-6 status light to be lit?

A

Any IR NI >/= 10E-10 Amps

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

When does P-6 status light go out?

A

BOTH IR NIs < 6E-11 amps

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is the function of P-6?

A

Permits manual block of auto SR High Flux Trip

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

When is P-7 met?

A

3/4 PRs < 10% AND 2/2 Turbine 1st stage Press < 10%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

When is P-7 deactivated?

A

2/4 PRs > 10% OR 1/2 Turbine 1st stage Pressure > 10%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the function of P-7?

A

Permits auto block of Rx Trips due to “at Power” Trips

  1. PRZ Press Low
  2. PRZ Water Level High
  3. RCS Loss of Flow
  4. RCP Bus UV
  5. RCP Bus UF
  6. RCP Breaker Position
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

How is P-7 made up?

A

Reset of P-10 and actuation of P-13

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

How is P-8 made up?

A

3/4 PRs = 29%

18
Q

How is P-8 cleared?

A

2/4 PRs > 29%

19
Q

What does P-8 doe?

A

Permits auto block of Rx Trips due to single loop low flow trips AND Turbine trip

20
Q

What conditions make up P-10?

A

2/4 PRs >/= 10%

21
Q

What conditions clears P-10?

A

3/4 PRs < 10%

22
Q

What does P-10 do?

A

Permits manual block of:

  1. PR High Flux Trip, Low SP
  2. IR Trip
  3. IR Rod Stop

Also

  1. Resets P-7
  2. Backup de-energization of SR
23
Q

What conditions make up P-11?

A

2/3 PRZ Press < 1920#

24
Q

What conditions clear P-11?

A

2/3 PRZ Press >/= 1910#

25
Q

What does P-11 do?

A

Permits manual block of SI on low PRZ Pressure

26
Q

What conditions make up P-12?

A

2/4 Loop Tavg = 541*F

27
Q

What conditions clear P-12?

A

3/4 Loop Tavg > 541*F

28
Q

What is the function of P-12?

A

Allows manual block of SI due to low steam line pressure

With High Steam Flow, gives Main Steamline Isolation

Blocks all Steam Dumps

29
Q

What conditions make up P-13?

A

2/2 Turbine 1st stage pressures < 10%

30
Q

What conditions clear P-13?

A

1/2 Turbine 1st Stage Pressures > 10%

31
Q

What conditions make up P-14?

A

2/3 SG NR Levels < 64 % in all 4 SGs

32
Q

What conditions clear P-14?

A

2/3 SG NR Levels > 678% in at least 1 SG

33
Q

What does P-14 do?

A

Allows or prevents MFW addition.

To prevent it, FWI initiated and MT and MFPs Trip

34
Q

What is C1?

A

Auto and Manual Rod stop when 1/2 IR @ 18 %(16%)

35
Q

What is C-2?

A

Auto and manual rod stop when 1/4 PR at 103%

36
Q

What is C-3?

A

Auto and Manual Rod stop and initiated Turbine runback when 2/4 OT delta T at 3% < Trip Setpoint

37
Q

What is C-4?

A

Auto and manual rod stop and initiates turbine runback when 2/4 OP delta T at 3% < trip setpoint

38
Q

What is C-5?

A

Rods Alive

Auto only rod stop when 1/1 turbine impulse pressure (MPC-253) < 15%

39
Q

What is C-11?

A

Rods in Heaven

Auto Rod stop only

When Bank D demand is at 229 Steps

40
Q

What is C-20?

A

2/2 Turbine Impulse Pressure > 40% enables AMSAC