What is the basis for not being critical with RCS Tavg belting less than 541*F?
MTC is within its analyzed temp range
Protective instrumentation is within its normal operating rage
PRZ is capable of being in an operable state w a steam bubble
Rx Vessel is above its minimum RTNDT temperature
What could happen if PRZ concentration is different than RCS concentration?
Outsure to the RCS. It may be borate or diluted, causing a RCS Temperature transient
After tripping the Rx, how long will it take for SR to energize?
10-15 mins
How many RCPs are required to be in operation with Tave > 541*F? Why?
All 4
Ensures protective instrumentation associated with the loops are operable
When is an RCS Sample for iodine required?
Load Reduction of 15% in 1 hour
If U2 is in mode 5 and the East RHR pump is in service, how is letdown flow affected if the RHR pump is lost?
LD flow is reduced due to loss of RHR pump discharge pump
Why is 600 gpm of RHR diverted to the HLs?
To ensure Loop 3 HL remains subcooled uring PRZ Outsurge
Why must NLI-151 be used with a correction figure during cool down to determine PRZ Level?
Cold Cal indicator compares the weight of the water in the PRZ vs the weight in the ref column. The cold cal was calibrated at 150*F, so there may be a density difference between the reference and the cold cal
Why is there only 1 RHR pump running at a time during half loop?
To prevent air entrainment
What mode must we be in tor remove power from RHR Suction valves?
Mode 5 to prevent closure. Must have power available in M4 for possible LOCA
How much heat is added from all 4 RCPs?
12-14 MW
Why is Hydrogen used to cool the main generator?
High thermal conductivity
Low windage losses
Non conductive
Non corrosive
Cheap
Criticality occurs in approximately how many doublings?
5 to 7
When is criticality declared?
Rx is actually super-critical, indicated by:
Constant + SUR
Rising Neutron counts rate without rod motion
What happens if you add positive reactivity when critical but below POAH?
Power rises until POHA or sufficient negative reactivity is added to stop the power rise