Roofing Flashcards
Widest board recommended for solid roof sheathing
6”
Spacing of wood shingles when installed on non-continuous sheathing
1x4” nominal dimension and spaced on center equal to weather exposure
At an eave end, drip edge is installed
Under the felt
Process of water backing up under shingles and leaking into ceilings as a result of freeze/thaw cycles of snow
Ice dams
NOT a method used for ice protection of asphalt and fiber glass roofing
1 layer of 90 lbs of hot mopped mineral based membrane
Approximate pounds of nails required per square of asphalt shingles
2.5
Recommended procedure for installing roll roofing
When temperature is above 45 degrees otherwise, otherwise cut shorter lengths and roll out under the sun
Bundles per square for Blue label cedar shingles
4
Type of flashing used for open valleys on a slate roof
15” copper
or
.0179 zinc coated
The weight if a coated vapor retarder for a built-up roof is usually about ___ to ___ pounds per square
45 to 80
Pounds of asphalt bitumen required per square between felts with an application tolerance of plus or minus 15 percent is
25
The most common type of asphalt _____
Type III
Max temperature to which you can heat type III Asphalt
475* F
Flash point of asphalt roofs
437 - 500* F
In built up roofs cant strips shall extend at least ____ inches up the vertical surface
5