Rooes And Tools Flashcards
Portable Generator:
If used to power exhaust fan, the ideal length of electric cord
50’ or less
Generator
Operate for how long
15 min weekly
Operate lights for 5 min test
Onboard generator check weekly at MUD
Waterproof connections hood for up to 3’ of water when mated
Utility Rope
LSR cut in 50’ lengths
All LAD and Sq carry min of 3
ENG carry min of 2
Telescoping Ladder
12’ telescoping open
Closed length 32”
32 lbs
Use NON Fire emergencies. NO heat resistance. Should NOT be secured at top or hung vertically
Useful at Elevators
it becomes WET wipe down and dry before storage. DO NOT use wax or parafin or oil or WD.
If lubricant needed use silicone based furniture polish (like Pledge) on beams.
Purple K Dry Chem
extinguisher
For METHENOL fires (also gas, diesel, compressed gas)
- discharge 19-20’
-11 seconds is discharge time
-Covers 30sq’
-direct at base of flames in a side to side motion
-LPG should NOT be extinguished unless source shut OFF
-ALWAYS upwind approx 10-12’ and 6” in front of fire
—EXCEPT flammable liquid pressure fire which is 15’ from leading edge
Water extinguisher
30lb
Water expelled in 55 seconds
Hydrostatic testing ever 5 years, if greater place OOS
100 psi and never set higher than 125psi
AFFF extinguisher
10 OZ
1 year
Inspected DAILY
Power Saw
Circle of danger
Circle of danger is 20’ RADIUS (40’ diameter)
1 slap= stop
2 slap= cut
3 slap= shut down saw
Fuel tank: 20-30 min