Engine Apparatus Flashcards

1
Q

Pump

A

2000 GPM
And Max pressure rating of 600 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

3rd Stage = High Pressure

A

Up to 700psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Idle pressure

A

Volume = 55psi
Pressure =110psi (to overcome head pressure)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How many folds equals 50’ of rolled hose

A

4 folds = 50’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

In-line Pumping

A

Any situation in which the 3 1/2” is used to connect to hydrant. Hydrant does NOT have to be before fire building (odd)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Drafting

A

Switch to RPM and throttle to 1000 rpm
Prime at least 45 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

ECC supplies standpipe

A

100psi, plus 5 psi per floor
ie fire in 26, 230psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

FDC with aluminum caps

A

Non-automatic or perforated pipe
Supply with 150psi

Automatic Sprinkler painted green

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Straight Run stairs are common in

A

Loft buildings and other larger occupancies (theatres)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

We’ll Hole stretch

A

Ideally, Hose strap placed just below coupling. Not necessary

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Rope stretch line through window on the ground floor

A

On ground floor the hose should pass through the UPPER pain of window, while pass through the LOWER pain on upper floor.

Rope stretch. Once enough hose hoisted in window (or roof) hose must be properly secured. This SHOULD BE done directly below COUPLING

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Fire escape stretch secure the hose secured where?

A

ONE hose strap on FE rail (not every other floor)
One floor below fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

ERP
Potential Detonation
What distance from suspected IED and PD not on scene

A

HT and CELL PHONES shall not be used within 150’ of suspended devices
APPARATUS, POST and MARINE RADIOS 300’. These are guidelines

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Pump Idle Pressure

A

Equals the pressure the pump provides at its lowest RPM (about 55 in volume or 110 in pressure). PLUS the intake pressure from water source like a hydrant (usually about 50)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

PD fully involved

A

Drop 2 handlines in front (bluff is 1 for TL)
Consider 2 1/2. WHIFE
Wind impact
Heavy involved 1st floor in large PD (Queen Anne)
Fully involved building
Exposure protection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Eng Pumper Mass Decon

A

25’ apart
50-80 psi
Aquastream in fog position

17
Q

High Rise Noz

A

2 1/2 shut-off permanently attached
1 1/8 MST removable checked WEEKLY at MUD
50psi and flow of 225GPM
Places into OPERATION direction of IC who MUST BE A CHIEF OFFICER
Officer order start water and iC operation
SSSS
SOLID BORE
STEEP ANGLE
STEADY STREAM
SPRINKLER EFFECT

18
Q

Custodian Wrench lost

A

Division has spare (3)
Engine does not have spare
Lost property FS-122

19
Q

Semi annual safety inspection of quarters. Conducted by…

A

The Engine CO SAFETY OFFICER in quarters housing MORE THAN 1 unit

20
Q

Outer stream Tip

A

Only OST used by FDNY is 1/2”
ONLY used for OVERHAUL

21
Q

Reverse Stair stretch

A

Approved by IC
Eng officer ID’s stairway and communicate to ECC AND IC.
ONLY officer of nozzle team can call for water

22
Q

Exterior Hose Drop

A

Approved by IC
-ECC stretches 2 1/2 to point lowered on ground.
-Floor BELOW 1st engine connect hose and lower out window
-AFTER hose lowered, must secure hose. MOST CRITICAL POINT OF EVOLUTION
-Rolling hitch (4 turns) below 1st coupling located outside window. Tied and secured BEFORE line charged
-Once tied line lowered outside window.
-After knot lowered into place, rope must be secured inside widow using substantial object knot.
-if kink, lift line to create a bow

23
Q

Clogged nozzle bc of ice/slush.
Solution?

A

Rapidly open and close nozzle repeatedly

24
Q

Failure of PPG

A

Switch to PRESSURE mode or Receive Relay from another pumper