Random Cards Flashcards

1
Q

HR Office
Fire Sector or Branch

A

Fire floor AND Floor below?
(Usually branch activated on 2nd alarm)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

HR office
Forward Staging Area

A

Floor BELOW the fire sector/branch to provide logistical support to fire sector/branch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

HR Office
Search and Evacuate Group/branch

A

Above fire sector
Coordinate all search and evacuation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

HR office
Forward Staging area

A

Upper floors where personnel and equipment I state of rediness

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

HR Office
Lobby Control Unit

A

Elevators at lobby.. search, recall control
Establish and control access points

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

HR office
System Control Unit

A

Control class E communication: HVAC
Evaluation of system operabilty..HT’s, hardwired phones, post radio, repeaters

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

HR Office
Staging Area

A

Located outside building

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

HR Officw
Forward Triage Area

A

Environmentally safe area on floor below Forward Staging Area

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

HR office
Staffing of Incident Command Post

A

1st arriving officer shall establish ICP. If he leaves ICP before arrival of chief officer designate member, preferably 1st LCC to note units entering and their destination

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

PPE Decon

A

Double clear bags with a EDR-1 between bags. (Red or BLk bags NOT acceptable)
PSS SEPARATE if grossly contaminated by other than foreground contaminates
All members with same contamination shall be listed on single form. Separate form for different contaminates

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Solar Panel
(Photovoltaic Electric Sys)

A

-Opening skylight/scuttle and horizontal vent prime focus of ladders
-water on PV system components only made by IC after careful size up.
-fog nozzle from a distance and set at 30 degrees
-straight stream and foam avoided since they are conductors
-Incipient fires can use Class C (dry Chem). **tricky.
-Lithium Ion batteries the use of Dry Chem or Foam proven effective for battery fires.
-metal tools away

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Fd/PD Tac U channel

A

Channel 12 (5 watts)
Use plain speak, no 10 codes
Each Bat has a yellow FAST HT capabile of Tac U

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

UTAC channel for Mutual aid Response

A

UTAC 42D is primary. Direct point to point (HT 9)
41D is secondary (HT 7)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Communication Unit staffed with

A

Min of 3 trained members and officers count
Does not need trained officers
Report to Communications Unit Leader of staffed. If not Resource Unit Leader, if not IC. Officer will not be Com Leader

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Lobby Control Unit
(Functional unit within Logistics Section)

A

Officer LCUL (leader)
Control, search elevators
Personnel entering/exiting
Provide transport
Take on duties of Sys Cont Unit when IC needs

Report to Logistics Section Chief or IC
Verify: Fire floor, Forward Staging Area, SAE post, forward triage

Equipment in every elevator car:
FE tools
spare cylinder
Elevator keys
Search rope
Elevator Control Sheet
Clipboard

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Proby notebook

A

Tool list 1st page of notebook
(Proby CONTROL Sheet attached to the inside cover of their Folder)
Keep notebook is office
Proby’s document all leaves
Probation extension continue journal

Review:
Privies review weekly and date in blue or black ink
Officer on duty each tour in red
Commander Monthly in red
Chief drill visits

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Proby Development

A

Successfully complete quiz at end of module print and staple receipt in their notebook

Control sheet inside cover of folder (BP 90)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Officer Shall NOT converse with chauffeurs Except

A

Speed, Route or Relay Information received by radio
SIR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

HYDRANT Shut Doen

A

COUNTER Clockwise 17 turns, noticeable decrease at 12
Nut is off center on street side of chamber

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

WIRES down in street

A

When life in danger: request power removal and priority response from utility. Request BC
-Check nearby buildings at fuse box, use TIC. No hand contact. DO NOT open house service. Heated wires can explode bc of CO build up
-Fog Noz AT LEAST 25 feet away from downed wire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

RING removal

A

Ring cutter can NOT cut stainless (regular pliers)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

WHEELCHAIR lifts in bus

A

Remove KEY and switch in OFF position
Secure/chock

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Rollover and Flashover occur during what stage of fire?

A

GROWTH stage

24
Q

Fully Developed (full room involved)

A

After compartment fire has FLASHED, the fire that remains is considered Fully Developed
Fire is ONLY Full Developed within the compartment that has flashed

25
Q

Decay Stage

A

All available fuel is consumed or when oxygen falls below 15%
So fire enters decay when either fuel limited or vent limited

26
Q

To see thermal interface (layer) the TIC has to be positioned where?

A

The TIC has to be positioned in the lower layer (cooler layer) looking up at the upper layer (hot layer). Camera in hot layer WON’T see thermal interface

27
Q

Neutral Plane

A

Occurs at vent opening. Indicates pressure differences and can help determine Fire Location

28
Q

Thermal Interface and interface height

A

Indicates heat difference and can indicate how far hot upper layer is banked Down and possibly of flashover

*different than neutral plane

29
Q

5 Characteristics of Smoke

A

Volume
Velocity
Density
Color
Stratification

30
Q

SMOKE seen issuing from CORNICE in tennament

A

UNDER NO Circumstance should cornice be opened for smoke in tenaments (iOLT or NLT)

31
Q

Trench Cut in H Type

A

At least 3” wide at narrowist section
About 20’ from initial vent hole

32
Q

FAST unit on Ch?

A

Ch-16
Ff in FAST radio ch 1

33
Q

company Drill

A

List of drill subjects recommended in Digital Drill calendar in Diamond Plate Homepage
M-F 1 hour
Standard time:
9x: 1400-1500
6x: 1900-2000

34
Q

MUD

A

At least 1.5 hours
No more than 2 Eng and 1 Lad, unless approved by DIV

PTO not be operated exceeding 30min

Radio contact upon leaving qtrs

35
Q

Window Bars (new)

A

Unit transmitting the 10-75 must give building description and state presence of window bars.
-Extra eng and truck (TL if one not already on 1st alarm)…including fast)
-Special called Lad can operate as a unit to remove
-ENSURE at least one window in fire floor and floor above cleared of bars. Portable/aerial/TL SHALL be placed to the window. Location of cleared windows should be communicated to all units

36
Q

GYPSUM ROOF

A

Gypsum planks and 2” thick, 2’ wide and 135lbs
Gypsum concrete roof is poured 2” thick and weighs about 17.5 lbs per sq foot

37
Q

BLADEs. (7/8 arbor)

A

Carbide tip (wood)
-8 or more from 24-tooth
-3 or more from 12

Abrasive (metal)
-painted yellow
-worn 8” or less

COMBO metal/concrete diamond (new)
-12”
-frequently back saw out
-excessive wobble discontinue use and inspect
-bidirectional, ignore directional arrows
-if glazed clean by running through abrasive material such as concrete
-gradually increase rpm when cutting

38
Q

HRFOMD 1st LCC

A

Outside survey
Deliver the LSR to floor above of Roof FF calls for it, unless can reach victim from street
If no outside opps team up with 2nd LCC and proceed to roof. ENSURE that bulkhead is NOT vented until fire knocked down!

39
Q

HRFPMD 2nd OV

A

If outside opps team up with 2nd LCC
-if no outside operate with 1st OV and secure another elevator
-If no fire service elevator team up with your officer
-if building has FREIGHT elevator that is remote from fire and can be used, notify IC and operate (when directed) with building personnel

40
Q

HRFPMD 3rd Lad

A

CONFIRM evacuation stair door closed on fire floor
When ROOF ops not covered by 1st and 2nd LCC then the IC may assign 3rd LAD.

41
Q

HRFPMD 10-77
Vent Support Group

A

6th DUE Lad assigned on 10-77
Priority order of PPV
- Pressurizing attack stairs
-Pressurizing evac stairs for smoke/CO
-Vent Public Hall for smoke/CO

42
Q

HRFPMD
Cellar fire and 1st line

A

When fire controlled by sprinkler AND connecting to standpipe would NOT expose members to IDLH the Eng officer CAN is Standpipe and contact IC

43
Q

HRFPMD
How long do you burp the bulkhead

A

60 seconds

44
Q

Standpipe OOS
When notify BC

A

-large life
-large property
-Change sprinkler head

45
Q

Community Assistance
-if civilian request assistance

A

Contact dispatch operating at a verbal alarm to assist civilian
-request PD

Letterhead report with endorsement to Chief of Operations and Journal entry w: name of civilian and police officer.

46
Q

Motor Vehicle Accident
-response

A

-Eng officer and TWO CFR go to scene
-Lad remove NEGATIVE terminal 1st
-Fire or hazard exist stretch and charge a hoseline

47
Q

PCBs
Energized Electric Transformers

A

Must be deactivated and equipment in off position performed ONLY by ConEd. NOT even under the direction of coned
Decon when exposed to PCB levels of 50PPM or higher

48
Q

Lost Metro card

A

Police report
Lost Property report
(Transit ID# on all reports)
Lost Prop report with Police Report NUMBER on it forwarded to RESOURCE CENTER

49
Q

Air train
-Guardrail above parapet means?

A

Guardrail Above parapet indicates 3rd rail located BETWEEN TRACKS and SIDE walkway present
NO GUARDRAIL visible above parapet indicates 3rd rail on OUTSIDE tracks and and walkway located between

50
Q

Stages of Modern Content Fires

A

Incipient
Rapid Growth
Vent Limited
Early Decay
Transition to Fully Developed (vent induced flashover)
2nd Decay

51
Q

Emergency Roll Call
Updated printout from Any MDT on scene, as follows;?

A

PRESS:
-INCIDENT SUMMARY
-SEND
-NEXT
-PRINT

52
Q

EMERGENCY CHANNEL (dedicated 5 watt) Chief can put member on this channel if the call
A MAYDAY

A

Channel 16

53
Q

Aerial Load capacity

A

250-750lbs at tip depending on elevation

54
Q

Correct TIME a unit can leave qtrs for training is..

A

0915 and 1815

55
Q

Pass it on program

A

IC
Emailed within 24 hours of operation
Can name unit or individual if positive

56
Q

Ice water tether rope…
Surf tether rope

A

Ice water tether rope 200’
Surf tether rope 600’

Night operations members not past line of site
All operating at or near water must wear PFD. Bunker gear in vicinity only when absolutely necessary