Random Cards Flashcards

1
Q

HR Office
Fire Sector or Branch

A

Fire floor AND Floor below?
(Usually branch activated on 2nd alarm)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

HR office
Forward Staging Area

A

Floor BELOW the fire sector/branch to provide logistical support to fire sector/branch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

HR Office
Search and Evacuate Group/branch

A

Above fire sector
Coordinate all search and evacuation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

HR office
Forward Staging area

A

Upper floors where personnel and equipment I state of rediness

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

HR Office
Lobby Control Unit

A

Elevators at lobby.. search, recall control
Establish and control access points

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

HR office
System Control Unit

A

Control class E communication: HVAC
Evaluation of system operabilty..HT’s, hardwired phones, post radio, repeaters

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

HR Office
Staging Area

A

Located outside building

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

HR Officw
Forward Triage Area

A

Environmentally safe area on floor below Forward Staging Area

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

HR office
Staffing of Incident Command Post

A

1st arriving officer shall establish ICP. If he leaves ICP before arrival of chief officer designate member, preferably 1st LCC to note units entering and their destination

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

PPE Decon

A

Double clear bags with a EDR-1 between bags. (Red or BLk bags NOT acceptable)
PSS SEPARATE if grossly contaminated by other than foreground contaminates
All members with same contamination shall be listed on single form. Separate form for different contaminates

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Solar Panel
(Photovoltaic Electric Sys)

A

-Opening skylight/scuttle and horizontal vent prime focus of ladders
-water on PV system components only made by IC after careful size up.
-fog nozzle from a distance and set at 30 degrees
-straight stream and foam avoided since they are conductors
-Incipient fires can use Class C (dry Chem). **tricky.
-Lithium Ion batteries the use of Dry Chem or Foam proven effective for battery fires.
-metal tools away

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Fd/PD Tac U channel

A

Channel 12 (5 watts)
Use plain speak, no 10 codes
Each Bat has a yellow FAST HT capabile of Tac U

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

UTAC channel for Mutual aid Response

A

UTAC 42D is primary. Direct point to point (HT 9)
41D is secondary (HT 7)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Communication Unit staffed with

A

Min of 3 trained members and officers count
Does not need trained officers
Report to Communications Unit Leader of staffed. If not Resource Unit Leader, if not IC. Officer will not be Com Leader

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Lobby Control Unit
(Functional unit within Logistics Section)

A

Officer LCUL (leader)
Control, search elevators
Personnel entering/exiting
Provide transport
Take on duties of Sys Cont Unit when IC needs

Report to Logistics Section Chief or IC
Verify: Fire floor, Forward Staging Area, SAE post, forward triage

Equipment in every elevator car:
FE tools
spare cylinder
Elevator keys
Search rope
Elevator Control Sheet
Clipboard

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Proby notebook

A

Tool list 1st page of notebook
(Proby CONTROL Sheet attached to the inside cover of their Folder)
Keep notebook is office
Proby’s document all leaves
Probation extension continue journal

Review:
Privies review weekly and date in blue or black ink
Officer on duty each tour in red
Commander Monthly in red
Chief drill visits

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Proby Development

A

Successfully complete quiz at end of module print and staple receipt in their notebook

Control sheet inside cover of folder (BP 90)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Officer Shall NOT converse with chauffeurs Except

A

Speed, Route or Relay Information received by radio
SIR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

HYDRANT Shut Doen

A

COUNTER Clockwise 17 turns, noticeable decrease at 12
Nut is off center on street side of chamber

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

WIRES down in street

A

When life in danger: request power removal and priority response from utility. Request BC
-Check nearby buildings at fuse box, use TIC. No hand contact. DO NOT open house service. Heated wires can explode bc of CO build up
-Fog Noz AT LEAST 25 feet away from downed wire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

RING removal

A

Ring cutter can NOT cut stainless (regular pliers)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

WHEELCHAIR lifts in bus

A

Remove KEY and switch in OFF position
Secure/chock

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Rollover and Flashover occur during what stage of fire?

A

GROWTH stage

24
Q

Fully Developed (full room involved)

A

After compartment fire has FLASHED, the fire that remains is considered Fully Developed
Fire is ONLY Full Developed within the compartment that has flashed

25
Decay Stage
All available fuel is consumed or when oxygen falls below 15% So fire enters decay when either fuel limited or vent limited
26
To see thermal interface (layer) the TIC has to be positioned where?
The TIC has to be positioned in the lower layer (cooler layer) looking up at the upper layer (hot layer). Camera in hot layer WON’T see thermal interface
27
Neutral Plane
Occurs at vent opening. Indicates pressure differences and can help determine Fire Location
28
Thermal Interface and interface height
Indicates heat difference and can indicate how far hot upper layer is banked Down and possibly of flashover *different than neutral plane
29
5 Characteristics of Smoke
Volume Velocity Density Color Stratification
30
SMOKE seen issuing from CORNICE in tennament
UNDER NO Circumstance should cornice be opened for smoke in tenaments (iOLT or NLT)
31
Trench Cut in H Type
At least 3” wide at narrowist section About 20’ from initial vent hole
32
FAST unit on Ch?
Ch-16 Ff in FAST radio ch 1
33
company Drill
List of drill subjects recommended in Digital Drill calendar in Diamond Plate Homepage M-F 1 hour Standard time: 9x: 1400-1500 6x: 1900-2000
34
MUD
At least 1.5 hours No more than 2 Eng and 1 Lad, unless approved by DIV PTO not be operated exceeding 30min Radio contact upon leaving qtrs
35
Window Bars (new)
Unit transmitting the 10-75 must give building description and state presence of window bars. -Extra eng and truck (TL if one not already on 1st alarm)…including fast) -Special called Lad can operate as a unit to remove -ENSURE at least one window in fire floor and floor above cleared of bars. Portable/aerial/TL SHALL be placed to the window. Location of cleared windows should be communicated to all units
36
GYPSUM ROOF
Gypsum planks and 2” thick, 2’ wide and 135lbs Gypsum concrete roof is poured 2” thick and weighs about 17.5 lbs per sq foot
37
BLADEs. (7/8 arbor)
Carbide tip (wood) -8 or more from 24-tooth -3 or more from 12 Abrasive (metal) -painted yellow -worn 8” or less COMBO metal/concrete diamond (new) -12” -frequently back saw out -excessive wobble discontinue use and inspect -bidirectional, ignore directional arrows -if glazed clean by running through abrasive material such as concrete -gradually increase rpm when cutting
38
HRFOMD 1st LCC
Outside survey Deliver the LSR to floor above of Roof FF calls for it, unless can reach victim from street If no outside opps team up with 2nd LCC and proceed to roof. ENSURE that bulkhead is NOT vented until fire knocked down!
39
HRFPMD 2nd OV
If outside opps team up with 2nd LCC -if no outside operate with 1st OV and secure another elevator -If no fire service elevator team up with your officer -if building has FREIGHT elevator that is remote from fire and can be used, notify IC and operate (when directed) with building personnel
40
HRFPMD 3rd Lad
CONFIRM evacuation stair door closed on fire floor When ROOF ops not covered by 1st and 2nd LCC then the IC may assign 3rd LAD.
41
HRFPMD 10-77 Vent Support Group
6th DUE Lad assigned on 10-77 Priority order of PPV - Pressurizing attack stairs -Pressurizing evac stairs for smoke/CO -Vent Public Hall for smoke/CO
42
HRFPMD Cellar fire and 1st line
When fire controlled by sprinkler AND connecting to standpipe would NOT expose members to IDLH the Eng officer CAN is Standpipe and contact IC
43
HRFPMD How long do you burp the bulkhead
60 seconds
44
Standpipe OOS When notify BC
-large life -large property -Change sprinkler head
45
Community Assistance -if civilian request assistance
Contact dispatch operating at a verbal alarm to assist civilian -request PD Letterhead report with endorsement to Chief of Operations and Journal entry w: name of civilian and police officer.
46
Motor Vehicle Accident -response
-Eng officer and TWO CFR go to scene -Lad remove NEGATIVE terminal 1st -Fire or hazard exist stretch and charge a hoseline
47
PCBs Energized Electric Transformers
Must be deactivated and equipment in off position performed ONLY by ConEd. NOT even under the direction of coned Decon when exposed to PCB levels of 50PPM or higher
48
Lost Metro card
Police report Lost Property report (Transit ID# on all reports) Lost Prop report with Police Report NUMBER on it forwarded to RESOURCE CENTER
49
Air train -Guardrail above parapet means?
Guardrail Above parapet indicates 3rd rail located BETWEEN TRACKS and SIDE walkway present NO GUARDRAIL visible above parapet indicates 3rd rail on OUTSIDE tracks and and walkway located between
50
Stages of Modern Content Fires
Incipient Rapid Growth Vent Limited Early Decay Transition to Fully Developed (vent induced flashover) 2nd Decay
51
Emergency Roll Call Updated printout from Any MDT on scene, as follows;?
PRESS: -INCIDENT SUMMARY -SEND -NEXT -PRINT
52
EMERGENCY CHANNEL (dedicated 5 watt) Chief can put member on this channel if the call A MAYDAY
Channel 16
53
Aerial Load capacity
250-750lbs at tip depending on elevation
54
Correct TIME a unit can leave qtrs for training is..
0915 and 1815
55
Pass it on program
IC Emailed within 24 hours of operation Can name unit or individual if positive
56
Ice water tether rope… Surf tether rope
Ice water tether rope 200’ Surf tether rope 600’ Night operations members not past line of site All operating at or near water must wear PFD. Bunker gear in vicinity only when absolutely necessary