What is it?
detection of up to 6 gases, standard includes 4. Sample draw gas monitor
What does the Eagle 2 detect?
Combustible gas
Carbon Monoxide
Hydrogen Sulfide
and % of oxygen in air
What are the 3 operating mode?
Normal- confined space
Bar Hole- underground gas leaks
Leak Check- valve or pipe leaks
What kind of pump and range?
125 ft, simple draw pump
Reaction time
30 seconds
Operating temp
-20 C to 50 C below 85% humidity
What is it calibrated to?
Methane
Types of batteries
4 size C/16 hours- alkaline 6.0 volts
4 size C/18 hours- Ni-MH- 5.2 volts
What type of sensor is the Oxygen?
Galvanic type
What type of sensor is the Catalytic Gas sensor (LEL)
uses catalytic elements for detection. current flows through it to detect gas
CO and H2S Sensor?
Electrochemical sensor that has 3 precious metal electrodes in a dilute acid
What 2 radio frequencies cause false alarms?
RF (radio frequency)
EMI (electromagnetic)
Low alarm indicator
ALRM1
alarm LED flashes 1 per second
Back light turns on
Pulsing tone once per second
High Alarm
ALRM2
Alarm LED flash twice per second
back laugh turns on
Pulsing tone twice per second
How to reset alarm?
POWER, ENTER, RESET