Which RHR pump supplies suction to the CCPs during CL Recirc?
East
Which RHR Pump supplies suction to the SI pumps during CL Recirc?
West
What is needed to open IMO-340, East RHR Hx to CCP Suction?
ICM-305, East RHR Pump Comte sump supply open and Either IMO-262 or 263 , SI Pump Recirc valve Closed
What is needed to open IMO-350, West RHR Hx to SI Pump Suction?
ICM-306, West RHR Pump Comte sump supply open and Either IMO-262 or 263 , SI Pump Recirc valve Closed
What is the set point for SV-103, RHR Cooldown Suction Line?
450 psig
What is the capacity of SV-103, RHR Cooldown suction line safety?
900 gpm
During LTOP, what are your modes of protection?
PORVS - 435 PSI if in cold over pressure
SV-103 - 450#
What are the RWST Tech Specs?
375,000 gals
70-100*F
2400-2600 ppm boron
What must be done before aligning RHR Spray?
Close RHR Loop injection valves before aligning spray to prevent runout
How many RHR Pumps can be ran during reduced inventory and why?
1 bc it could cause air entrainment at Loop 2 suction
How many RCS Loops are needed in Mode 4?
Can any be removed from service?
2 RCS or RHR Loops
All loops can be removed for 1 hour per 8 hours if no dilutions to violate SDM and core out temp > 10*F below sat temp
How many RCS Loops are needed in M5 with loops filled?
Can any loops be taken out?
1 RHR Loop and 1 more RHR Loop OR 2 SG water levels 420” > WR Level Instrument.
1 RHR pump can be our for 1 hr per 8 hrs if:
1 RHR Loop may be INOP for 2 hrs for testing IF other RHR Loop is operable and in operation
How many RCS Loops must be operable in M5 with loops drained?
Can RHR Loops be out at any time?
2 RHR Loops Operable, with 1 loop in operation
All RHR can be out for < 30 mins when switching loops IF: No dilutions violate SDM and Core out temp > 10*F below sat temp and No more draining RCS volume of boring reduction
1 RHR Loop can be INOP 2 hrs for testing if other RHR loop is OPERABEL and in operation
How many RHR loops are needed in M6 with >= 23ft above top of Rx vessel flange?
May any loops be removed?
1 RHR Loop Operable.
May be removed for 1 hr / 8 hr period with no dilutions allowed
How many RHR Loops are needed to be operable in M6 with < 23 ft above the Rx Vessel Flange?
2 RHR Loop operable with 1 in operation