After Thoughts Flashcards

1
Q

What is the interlock with both CCP breakers open?

A

LD Orifice Valves will close

QRV-160, 161, and 162

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What will close the LD Orifice Valves? (4 things)

A

Phase A

When either LD Isolation Valve is closed

Loss of both CCPs

PRZ Level at 17%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the interlock to open the LD Isolation Valves?

A

Will not open if any orifice isolation valve is open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the interlock with IMO-128?

A

NPS-122, Loop 1, Ch 3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the interlock with ICM-129?

A

NPS-121, Loop 2, Ch2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

After swap to CL Recirc, how long do you have to isolated the SAT?

A

5 minutes to keep the NAOH from messing up the pH

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How do you adjust the temperature for the H2 Recombiners?

A

Adjust the KW

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the MFP low condenser vacuum trip?

A

U1 = 20” Hg

U2 = 20.3” Hg

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the MFP Low LO pressure trip?

A

4# with a 5 second time delay

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the Low Suction pressure MFP Trip?

A

180# with a 5 sec time delay

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the Low Pressure auto start for CCW?

A

80#

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is the low pressure auto start for ESW?

A

40#

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is the Low Pressure auto start for NESW?

A

U1 = 55#

U2 = 60#

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What are the design features to prevent SFP from draining?

A

No Gravity Drains

Suction’s 19.5” below surface

Return Lines > 6’ above fuel

Anti-Siphone Holes 4” below surface

Skimmer 6” below normal surface

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the low pressure autostart for the CBP?

A

325#

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is the low pressure auto start for the hotwell pumps?

A

130#

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

RCDT Inputs?

A

Accumulator Drains

RCS Loop Drains

Regen and XS LD HX Drains

RX Vessel Flange Leakoff

Refueling cavity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

What is the U1 Turbine Low Vac Trip from DCS?

A

24.1” Hg

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

What is the U1 Turbine Trip from Low Oil Pressure?

A

8 psig for > 5 secs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

What is the U2 Turbine Trip from Low Vacuum?

A

20.3” Hg

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

What is the U2 TUrbine Trip from Low Oil Pressure?

A

14.7 psig for > 5 secs

22
Q

What is the input to the RIL Computer?

23
Q

What are the PRT Inputs?

A

Seal Return Safety

ECCS Safeties

RHR Suction, HL Discharge and Hx Safeties

CCP Safeties

24
Q

What temperature does the Turbine Trip Steam Dump controller control at?

25
What temperature does the Load Rejection Controller control at?
552* F Rods take care of the other 5*
26
What is the input for the MFP DP Setpoint?
Total Steam Flow
27
What is the alternate power supply for the CRIDs?
600V thru the Isolimeter
28
If the CRID is on the alternate source of power (600 V), what is the status of the Inverter and Bus?
Inverter = INOP Bus = OPERABLE
29
If the CRID is on CRP-3 power source, what is the status of the CRID Bus?
INOP
30
What’s the MS pressures for U1 and U2 at 50% power?
U2 will be higher than U1 due to the higher temperature at which it operates
31
Steam dumps are in steam pressure mode and fail open. What is the minimum action to stop the cooldown involving the switches?
Take 1 switch to off
32
What’s the basis of the 46K FO Storage Tank Tech Spec?
1 EDG for 7 Days
33
What is a DAC hour?
1 DAC Hr = 2.5 mrem
34
How does IRV-311 fail on a loss of CA?
Open
35
A High rad on which Rad Monitor meets entry Conditions for Irradiated Fuel Handling Accident in Containment - Control Room Actions?
VRS-1500, Vent Stack
36
What are the SC requirements during NC with and without CRDMs?
90*F with CRDMs 220*F without CRDMs
37
What would result in immediate suspension of core alts?
Loss of comms between the Control Room and Fuel Handling People
38
When evacuating the CR, how is CVCS cross-tie done and how is it monitored?
Opp Unit CCP suction to the RWST. Flow is tracked by the U1/2 cross-tie flow indicator
39
How does the AEO Trip the Rx Locally in FRS-1?
Rx Trip Breaker (1) Rx Trip Bypass Breaker (1) MG Set Output Breakers (2)
40
Has significant fuel damage occurred when CETs are at 1200*F?
No
41
Which procedures can you transition to from the immediate actions of E-0?
ES-0.1 if SI is not actuated or required ECA-0.0 if no power to either A or D T bus FR-S.1 if Rx Trip is unsuccessful
42
What is the order of preference for depressurization in ES-1.2, Post LOCA Cooldown and Depressurization?
1. Normal Spray 2. PORV 3. Aux Spray
43
What is indicative of a RCP Thermal Barrier Hx Failure?
RCP Alarms CCW Surge Tank Level Rising RCP Cooling water flow mismatch
44
Which pump is the CCW Misc Hdr aligned to first when splitting trains out to identify the leak?
East
45
What is used to determine with PRZ PORV is leaking?
Rising PORV Discharge Temp
46
During a SG Tube Leak, when would you trip the RX and SI?
RCS SC < 40*F PRZ Level is not able to be maintained SG Tube Leak of > 100 gpm
47
What are the indications of #1 RCP Seal Failure?
SLO Flow Lowering or Raising (depending) #1 Seal DP LOwering #1 SLO Temp RIsing Lower Bearing Water Temp Rising
48
What are the indications of a # 2 Seal Failure?
#1 SLO Flow Lowering (usually) or Rising RCDT Level / Temp Rising RCP Standpipe Level High Vibes rising
49
If you lose a Train of 250 VDC, what will cause a Reactor Trip?
RCP Bus UF / UV
50
A loss of which train 250 V DC will NOT trip the generator and why?
Train A bc it powers 33 VED
51
Which Tain of 250 VDC powers annunciators?
Train A
52
A loss of which train of 250 VDC will cause all 9 steam dump valves to be blocked closed?
Train A