Residential Drainage, Waste And Venting Flashcards

1
Q

Piping should be installed so their markings are ______ and _____

A

Facing up when installed in a trench and facing down when hung on hangers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

When installing pipe underground, the ditch should be __________

A

Smooth and without any high spots

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

When placing any pipes under or through a foundation you should prevent the foundation from _______

A

Bearing any weight on the pipe

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When back filling a trench the first _____ mm should be done by hand using small compatible aggregate

A

300mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Can you use a sanitary T on its back to connect one fixture drain to another ?
Explain

A

No

A sanitary T on its back can only be used to connect a dry vent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Does ABS pipe expand more than PVC

A

Yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Can you purchase a 2” expansion joint

A

Yes

Sizes 1 1/2 “ to 4”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The maximum trap arm length of a minimum size floor drain is _____ m or ______ feet

A

2.4 meters or 8 feet

2” floor drain

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

When can you have a floor drain trap arm only 2 pipe diameters in length?

A

A floor drain trap arm can be as close as 2 pipe diameters when it has its own vent, otherwise better not connected to a building drain, the trap arm is required to be at least 18” in length.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The size of a clean out is determined by the size of the________

A

Drainage pipe, but does not need to be larger than 4” for pipes over 4”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

If you have a 4” building drain connected to a 3” soil stack, what would the size of the clean out be at the base of the stack?
Why?

A

4” because the clean out is for the building drain, and a clean out must be the same size as the drain it serves.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

When you are uncertain if a bathtub trap will be accessible or non-accessible, what would be the solution?

A

Install a solid p trap, a clean out on the trap arm right after the trap and a clean out on the waste and overflow . This will allow for cleaning the trap and the arm after the trap

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is the cheapest method of venting?

A

Stack vent is the most economical method. This wet vent method allows one vent to serve many fixtures.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Can you have 2 basins tied together by a continuous waste system?

A

Yes. There can be 2 single compartment sinks or 2 basins on one trap using the continuous waste method, as long as limitations in distance are followed.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Can you have a 1 1/4” waste branch?

Table ____

A

Yes
Table 2.4.10.6.B states that a branch having 2 fixture units can flow through an 1 1/4” drain. In this case, 2 basins could be tied together, as in dual and continuous venting.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

A wet vent will be sized according to what table?

A

Table 2.5.2.1

17
Q

If a fixture is not listed on table 2.4.9.3, the size of the trap will determine its fixture units using Table _______

A

Table 2.4.10.2

18
Q

According to the NPC, to size a building drain, you must know the _______and _______

A

The total fixture units
And
The amount of grade on the pipe

19
Q

According to table Table 2.4.9.3, the smallest p trap is ______ inch for one shower head.

A

1 1/2

20
Q

How do you size a continuous vent?

A

A continuous vent is sized according to its developed length and the amount of fixture units venting through that vent, then size according to the largest trap that it serves.

21
Q

How do you decide the size of the trap arm?

A

A trap arm is sized either by table 2.4.9.3 or according to its fixture outlet size .

22
Q

What is the advantage of a bungalow fitting?

A

The bungalow fitting allows 2 trap arms to be connected at the same level. The water closet is the main connection with the option of a right or left hand outlet to the 3” inlet with a choice of 1 1/2” or 2” in size. It is great for keeping stack vented fixtures high in the joist space.

23
Q

Why is a material list so important for a job?

A

A material list assists in tracking materials that are used or required on a particular job

24
Q

Does a plumbing vent that is installed above the flood level rim of a fixture need to be leak tested?
Why?

A

Yes?

The NPC says that all DWV system need to be tested for leaks.

25
Q

What is the minimum time required for a leak test using water?

A

15 minutes

26
Q

When performing a final test why can you not exceed 1” water column of pressure?

A

If the pressure were to increase, the air or smoke would make its way out of the traps by forcing the water out of the trap seal of by bubbling through the trap seal.

27
Q

When pressure testing a drainage system, what is the tool needed to hold the pressure in the piping being tested?

A

A test plug