Radwaste Flashcards

1
Q

What does the RWCU phase separators overflow to?

A

overflow to each other. then when full, overflows to Radwaste building tank ventilation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

what drains into the waste holding tanks?

A

Equipment filter goes into waste holding tank A

Floor filter goes into waste holding tank B

Waste holding tank C normally not used except as a supply tank for the alternate bodyfeed pump if needed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What temp should water be maintained at and why?

A

< 140 deg F to keep from degrading resin

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

If G17-F087A and F087B are closed, what other 2 valves are affected?

Why are these interlocked?

A

F106A won’t close
F106B won’t open

Allows flow path to prevent overflow of floor drain separator

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What’s the purpose of Distillate Sample Tank?

A

Collect and store water from SLC surveillance. Discharges to river

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What’s the purpose of the waste surge tank?

A

collects condensate demin water

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What’s the purpose of liquid radwaste?

A

Process and either recycle or dispose of liquid radwaste. Either sent to CST or River while being monitored

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What’s the purpose of the floor drain oil separator tank?

A

ensures oil doesn’t enter liquid radwaste system and contaminate resin.

separates oil from the water steam that goes in floor drain collector tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What will auto close the G17-F355 discharge basin isolation valve and force it to stay closed?

How do you reopen the valve after this occurs?

A

HI-HI Rad alarm on Radwaste effluent discharge

Using Key locked handswitch in Control Room

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

what will auto open and close the G17-F355 valve?

A

Auto close on Circ water blowdown flow low re-opens when cleared

Auto close after receiving high discharge flow will re-open when the flow drops below setpoint (usually 100 gpm)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

When should the funda filters be backwashed?

A

When filter screens reach 20 cu. ft. or high DP of 60 psid

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What tank is normally used for filling the CST?

A

Equipment drain sample tank

How well did you know this?
1
Not at all
2
3
4
5
Perfectly