Lube Oil Conditioning Flashcards

1
Q

What will trip if the F045 (Lube oil conditioning inlet valve) is CLOSED?

A

Lube oil conditioner pump will eventually trip on low tank level if valve doesn’t re-open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What’s the maximum level that can be put into clean oil storage tank when transferring into it?

A

20 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Who should be contacted prior to transferring oil from outside storage tank to an offsite location?
Why?

A

RP and Chemistry.

Need to perform isotopic test

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What’s the purpose of the lube oil system?

A

Continuously purifies the main turbine and Reactor feed pump turbines’ lube oil reservoirs and provides storage tanks for storing clean and dirty oil.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How does oil get into the lube oil conditioner?

A

gravity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What’s the purpose of the lube oil transfer pump?

A

used to transfer oil between storage tanks and reservoirs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What’s the purpose of the vapor extractors?

A

maintain vacuum in vapor space in reservoirs to prevent buildup of explosive mixture of gases

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What will trip the vapor extractors?

A

sprinkler system or deluge system is initiated

flow switch in system detects this

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Where do the vapor extractors exhaust to?

A

Roof of turbine building

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Purpose of the lube oil conditioning pump?

A

Remove oil from conditioner through polishing filters and return the oil either back to reservoirs or to one of the lube oil storage tanks.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What will trip the lube oil conditioner pump?

A

tank level too low on clean oil compartment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Will the lube oil conditioner pump auto restart after a trip?

A

Yes, if hand switch is not in STOP.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

How does the F045 valve fail?

A

closed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

what will auto-close the F045 valve?

A

HI level Inlet compartment on top of the ‘A’ or ‘B’ filtering unit.

Hi level conditioners clean oil compartment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Will the F045 valve auto-reopen after an auto close signal?

A

Yes, when the condition clears

How well did you know this?
1
Not at all
2
3
4
5
Perfectly