What systems is the RD system used to detect leakage in?

A

RCS,refueling pool, ESF equipment room and SFP

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

Where does the radioactive drains system receive waste from?

A

Ctmt, aux building, radwaste bldg, fuel bldg, yard hut area, decontamination facility (unit 1 only) and the MSSS.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What system provides sump pump bearing lubrication for the RD system?

A

DW

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What system is used to operate the RD containment isolation valves?

A

IA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What system provides power for the inside containment ISO valves?

A

PH

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What system provides power to the outside containment ISO valves?

A

PK

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Where are all of the rd sumps pumped to?

A

LRS system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Where is the RD system vented to?

A

HR
HA
HS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Where is the reactor cavity sump vented to?

A

Ctmt bldg atmosphere

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Where does the west ctmt building sump receive drains from.

A

Floor and equipment drains, refueling pool, refueling pool liner plate leak detector compartment.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Where does the east ctmt sump receive drains from?

A

Floor and equipment drains and the refueling pool.

Second penetration receives from Rx cavity sumps.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Where are the east and west ctmt sumps vented to?

A

Ctmt atmosphere.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Where are the ESF sumps penetrations from?

A
Sdchx
CS pump room
HPSI pump room
LPSI pump room
Pipe chase area room
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Where are the ESF sumps vented to

A

HA exhaust duct

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Where does the non ESF sump receive drains from?

A

Non ESF floor drains and equipment drains located throughout the aux bldg
Additionally a stainless steel pipe from the equipment drain tank relief valve is routed through the cover plate and into the sump.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Where is the non ESF sump vented to?

A

HA exhaust duct

16
Q

Where are the non ESF sump pumps located?

A

40’ of aux bldg next to the sumps.

17
Q

Where does the radwaste bldg sump receive drains from?

A

Floor and equipment drains from the radwaste building and charging pump oil drain tank drains directly to the sump

18
Q

Where is the radwaste sump vented to.

A

Radwaste building HVAC exhaust duct

19
Q

Where does the fuel building sump receive drains from?

A

Floor and equipment drains throughout the fb
Cask decon pit
FP liner leak detector
Cask pit

20
Q

Where does the FB sump vent to?

A

FB atmosphere.

21
Q

Where does the holdup tank area sump receive drains from?

A

Rmwt
Holdup pump room
RWT overflows
HUT overflow

22
Q

Where is the HUT area sump vented to?

A

Atmosphere.

23
Q

Where does the decon facility located only in unit one pump to?

A

Chemical drain tanks

24
Q

What happens if a hi hi level occurs in a radwaste building sump?

A

An alarm is lit in the control room and the radwaste control room.

25
Q

What system supplies power to the radwaste sump pumps?

A

NHN

26
Q

How does a loss do radioactive drains effect the plant?

A

Sumps would eventually overflow and there would be a radioactive spill

27
Q

What happens to the RD system in the event of a LOCA?

A

Outside of contamination ISO valve will be closed from the control room to isolate flowpath from the ESF and non ESF sumps to the I radwaste building.