Oily Waste And Non Radioactive Waste Flashcards
What is the purpose of the ow system?
Provides a single collection point for an oil/water mixture at the oily water separator, where oil is manually skimmed and removed.
Where does the ow system collect system waste from?
Turbine, control, DG, fire pump house and yard area.
How are the sumps operated?
Local switch two pumps that alternate.
What provides sump pump intermediate and case bearing lubrication for the control building?
Demineralized water
What provides intermediate and case bearing lubrication for the DG building?
Domestic water
What prevents the over pressurization of sump pump bearings?
Pressure control valves.
What happens if the sumps receive a hi hi level?
Alarm in control room and second pump starts.
How many turbine building sumps are there in the turbine ow system?
One
How many condenser area sumps are there in the turbine bldg OW system?
2
Where is the up discharge of the sump pumps directed if there is chemicals in the liquid?
Chem waste neut tank
Where is the liquid from the discharge of the sump pumps directed if radioactive particles are detected?
LRS huts
Where is water collected from the battery room in the switchgear building directed?
Acid neutralizing sumo before draining to the north condenser area sump.
Where does the non class battery room neutralizing sump go?
North condenser area sump
Where does the A train battery neutralizing sump drain to?
West control building sump
Where does the B train battery room acid neutralizing tank drain to?
East control building sump.