Rad monitors Flashcards

1
Q

What causes the blue alarm beacon?

A

No sample flow

No radiation detected

Too much radiation detected

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What causes a red alarm beacon?

A

High radiation in effluent stack

Sample flow too high or too low

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What’s the purpose of ARMs?

A

Monitor and record the gamma radiation levels in various areas throughout the plant so that personnel are not inadvertently exposed to high radiation doses

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How many ARMs do we have?

A

50

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How many drywell and CTMT high range ARMs do we have?

where are they?

what type of detector is this?

A

4

2 in Drywell, 2 in Containment

Ion Chamber

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What are the process Rad monitors and where are their locations?

A

CTMT and DW vent 166’ Area 8

FHA/Fuel Pool Sweep 245’ Area 9

Turbine building vent 166’ Area 4

Radwaste ventilation RW 136’

SBGT A/B 245’ Area 9

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What are the process liquid rad monitors and where are they located?

A

PSW 93’ area 9

SSW A/B 93’ Area 9 - A, Area 10 - B

CCW 119’ Area 9

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What’s the purpose of process rad monitoring?

A

Initiate appropriate protective action to limit release of radioactive materials from reactor vessel, primary and secondary CTMT, if predetermined levels are exceeded in major effluent streams.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Which SBGT sample pump is always running?

A

B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What causes offgas post treatment rad monitor to trip?

What valve closes when this happens?

A

2 upscale Hi Hi Hi trips
2 downscale trips
1 downscale and 1 Hi Hi Hi trip

Closed N64-F060 which also closes the N64-F023, F034A/B, F054

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What will cause radwaste effluent rad monitor to trip?

What valve isolates?

A

Hi Hi rads
Monitor downscale
Monitor inop

G17-F355

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What could high rad level in the offgas post treat rad monitor be a sign of?

A

Early indication of catastrophic fuel failure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly