Quizlet: Home Inspection Flashcards
A wall supporting any vertical load in addition to its own weight is a ___-___ wall.
Load-bearing
Openings from a private garage directly into used for sleeping purpose shall ___ be permitted.
Not
The building permit or copy thereof shall be kept on site of work until the __ of the project.
Completion
Shower compartments shall have at least ___ square inches of interior cross-sectional areas.
900 sq.in.
Wall and ceiling finishes shall have a flame-spread classification of not greater than ____.
200
Ramps shall have a maximum slope of ___ until vertical in ___ units horizontal (8.3% slope).
1 vertical, 12 horizontal
Other habitable rooms shall have a floor area of not less than ___ square feet.
70 sq. ft.
Final inspection shall be made after the permitted work is ____ and prior to ____.
Complete, Occupancy
Every dwelling unit shall be provided with a water closet, lavatory, and a bathtub or shower.
True or False
True
Fuel-gas-fired domestic clothes dryer ducts shall be a minimum of ___ inches in diameter.
4 inches
Every landing shall have a minimum dimension of ___ inches measured in the direction of travel.
36 inches
Each dwelling unit shall be provided with a kitchen area and every kitchen area shall be provided with a ___.
Sink
Wall and ceiling finishes shall have a smoke-devloped index of not greater than ___.
450
Glazing in swinging doors, except jalousies shall be considered a specific _____ location.
Hazardous
Standpipes shall extend a minimum of ___ inches and a maximum of ____ inches above the trap weir.
18 inches, 42 inches
Supports for 1 inch copper or copper alloy tubing run horizontal shall not be spaced more than ___ feet apart.
6 feet
The grade away from foundation walls shall fall a minimum of ___ inches within the first ___feet.
6 inches, 10 feet
A permit is not required for retaining walls that are not over ___ feet in height, unless supporting a surcharges.
4 feet
The minimum headroom in all parts of the stairway shall not be less than ____ feet, ____ inches.
6 feet, 8 inches
In areas subject to decay damage, naturally durable wood or wood that is preservative treated shall be used.
True or False
True
The center line of water closets or bidets shall not be less than ___ inches from adjacent walls or partitions.
15 inches
All exterior footing shall be placed at least ___ inches below the undisturbed found.
12 inches
Sinks shall be provided with waste outlets not less than ___ inches in diameter.
1 inch
A Type B-W gas vent shall terminate at least ___ feet in vertical height above the bottom of the wall furnace.
12 feet
Water service pipe shall be installed not less than ___ inches deep or less than ___ inches below frost line.
12 inches, 6 inches
Underground fuel gas piping systems shall be installed a minimum depth of ___ inches below grade.
12 inches
Gas appliance fuel connectors shall have ll length not to exceed ___ feet.
3 feet
Clothes dryer transition ducts shall be metal and limited to a single length not to exceed ___ feet.
8 feet
The maximum amount of fuel oil stored above ground or inside a building shall be ___ gallons.
660 gallons
Polyethylene tubing for hydronic piping systems shall installed with heat fusion joints.
True or False
True
The lowest portion of a gas floor furance shall have not less than ___ inch clearance from grade level.
6 inches
At least one outlet in bathrooms is required to be within ___ inches of each lavatory basin.
36 inches
When mechanical equipment is located in attics, it shall not be further than ___ feet from the attic access.
20 feet
Receptacles installed on 15- and 20-ampere-rated branch circuits shall be of the ___ type.
Grounding
The bottom surface of footing shall have a slope excceding ___ unit vertical in ___ units horizontal (10-percent slope).
1 vertical, 10 horizontal
Appliances suspended from the floor shall have a clearance of not less than ___ inches from the ground.
6 inches
What is the minimum uniformly distributed live load for sleeping rooms?
30 pounds per square foot
In no case shall the point of attachment for service-drop conductors be less than ___ feet above finish grade.
10 feet
Branch circuit rating for space-heating and water-heating appliances shall be considered ___ loads.
Continuous
In calculating box fill each No. 12 AWG conductors shall require ____ cubic inches free space within the box.
2.25 cubic inch
The minimum width of the handrail above the recess shall be ___ inches to a maximum of ___.
1.25 inches, 2.75 inches
Ceiling-suspended paddle fans shall be supported independently of the outlet box.
True or False
True
Foundations for masonry chimneys shall be constructed of concrete or solid masonory at least ___ inches thick.
12 inches
Where subject to physical damage, cable may be protected by Scedule 80 PVC rigid nonmetallic conduit.
True or False
True
Flanges and lips of load-bearing steel floor framing members shall ____ be cut or notched.
Not
The minimum required under-floor access opening shall be ___ inches by ____ inches to all under-floor spaces.
18 inches by 24 inches
The minimum thickness of masonry fireplace hearths shall be ____ inches.
4 inches
Conductors shall have a vertical clearance of not less than ____ feet above the roof surface.
8 feet
Where installed in raceways, conductors of size NO. ____ and larger shall be stranded.
8
The minimum headroom for working spaces for service equipement and panelboards shall be ____feet.
6.5 feet
For one-family dwellings, the rating of the underground conductors shall be not less than ____ amperes, 3 wire.
100 Amp
A minimum length of ____ inches of free conductor shall be provided at each outlet, junction, or switch point.
6 inches
Working space in front of panelboards shall not be less than ___ inches in depth and ___ inches wide.
36 inches, 30 inches
The studs used in wood foundation wall shall be ___ -inch by ___ -inch members.
2-inch by 6-inch
Wood sill plates shall be a minimum of ___-inch by ____-inch nominal lumber.
2-inch by 4-inch
Chimneys that pass through a soffit or cornice shall have a minimum air space clearance of ____ inch.
1 inch
Handrails shall not project more than ____ inches on either side of the stairway.
4.5 inches
The minimum openable area to the outdoors shall be ____ percent of the floor area being ventilated.
4%
Attic access rough-framed openings shall not be less than ___ inches by ___ inches.
22 inches by 30 inches
Holes in steel wall studs shall not exceed ____ inches in width or ____ inches in length.
1.5 inches, 4.5 inches
Studs in nonbearing partitions may be notched to a depth not exceeding ____ perent of a single stud width.
40%
The minimum thickness of masonry bearing walls more than one story high shall be ___ inches.
8 inches
Stone or masonry veneer above openings shall be supported on lintels of ____ materials.
Noncombustible
Collar ties shall be a minimum of 1-inch by 4-inch, spaced not more than ____ feet on center.
4 feet
The construction of braced walls may be of gypsum board with a minimum ____ inch thickness.
1/2 inch
Wood framing supporting gypsum board shall not be spaced more than ____ inches on center.
24 inches
Water heaters having an ignition source shall be elevated such that the source of ingnition is not less than ___ inches above the garage floor.
18 inches
The garage shall be separated from the residence and its attic area by not less than ____ inch gypsum board or equivalent applied to the garage side.
1/2 inch
Where openings are provided as a means of escsape and rescue they shall have a sill height of not more than ___ inches above the floor.
44 inches
Wood shakes shall only be used on slopes of ____ units vertical in ____ units horizontal (25-percent slope) or greater.
3 in 12
Gas vents 12 inches or larger shall terminate nott less than ___ feet above the highest point where they pass through the roof.
2 feet
Kitchen countertop receptacles shall be installed so that no point along the wall line is more than ___ inches from a receptacle.
24 inches
Where used outside, aluminum or copper-clad aluminum grounding conductors shall not be installed within ___ inches of the earth.
18 inches
Appliances having an ignition source shall be elevated such that the source of ignition is not less than ____ inches above the floor in garages.
18 inches
The maximum length of a clothes dryer exhaust duct shall not exceed ___ feet from the dryer location to the wall or roof termination.
25 feet
Manually operated dampers shall not be installed except in connectors or chimneys serving solid-fuel-buring appliances.
True or False
True
A minimum of ___ 20-ampere branch circuit shall be provided to supply the bathroom receptacle outlets. Such circuit shall have no other outle.
One
Nonmetallic boxes shall be used only with nonmetallic-sheathed cable, cable wiring methods, flexible cords and nonmetallic raceways.
True or False
True
Bathrooms … shall be provided with aggregate glazing area in windows of not less than ____ square feet, one-half of which must be openable.
3 square feet
Over residential property and driveways, service-drop conductors shall have _____ feet minimum clearance above final grade.
12 feet
On stairways the greatest riser height within any flioghtt of stairs shall not exceed the smallest by more than ____ inch.
3/8 inch
Cleanouts shall be not installed not more than ____ feet apart in horizontal drainage lines measured from the upstream enterance of the cleanout.
100 feet
Exterior walls with a fire separation distance less than ___ feet shall have not less than a one-hour fire-resistive rating with exposure from both sides.
5 feet
Habitable rooms, hallways, corridors, bathrooms, toilet rooms, laundry rooms and basements shall have a ceiling height of not less than ____ feet.
7 feet
Dwelling units shall be provided with heating facilites capable of maintaining a minimum room temperature of ____ F.
68 degress
Habitable rooms shall not be less than ___ feet in any horizontal dimension.
7 feet
Lavatories shall have waste outlets not less than ___ inch in diameter.
1.25 inch
Recessed incandescent fixtures shall have ____ protection.
Thermal