Pzr Pressure and Lvl Control Flashcards
What is the normal Lvl, temp, and # of the PRT?
- 100°F
- 83%
- 3#
When will the PRT vent valve not open?
> 10#
What is the max # of the PRT?
- 100# (Rupture Disk)
What is the PRT designed to do?
- Condenses 110% of Pzr steam space
- Protects the Rx Vessel against brittle fracture during LTOP conditons
- Provides overpressure Protection
What are the inputs to the PRT?
- Pressurizer Safeties and PORVs
- Seal Water Return Safety
- CCP Suction Safeties
- ECCS Safeties
- RHR Suction Safety
- RHR Hot Leg Discharge Safety
- RHR hx Safeties
- PW and N2
What is the lvl per percent in the Pzr?
75gal / 1%
What is the Pzr Lvl Program based on?
Based on Auctioneered High Tave
- Unit 1 - 22% to 50% (28% diff)
- Unit 2 - 22% to 55% (33% diff)
What are the Pressure inputs for the Pzr Pressure Ctrl?
NPP-151
NPP-152
NPP-153
NPS-153
At what pressure do the Pzr Safeties lift?
2485# (SV-45A/B/C)
At what pressure do the Pzr PORVs open?
2335# (NRV-151/152/153)
Which Pzr PORVs have backup air bottles?
NRV-152/153
What supplies the PRT with water if it needs to be filled or if it gets > 126°F during normal ops?
PW
Which Safeties and PORVs have acoustic monitors?
- Safeties- 1 monitor for each safety valve (3 total)
- PORVs- 1 monitor total (combined)
What are the Lvl inputs for the Pzr Lvl Ctrl?
- NLP-151 (Ctrl Channel)
- NLP-152 (Bistable)
- NLP-153 (Either Ctrl or Bi)
- NLI-151 (cold cal)
What is the Rx Trip setpoint for Pressurizer Level?
92%
What are the Pzr Cycling Heater trips?
- Loadshed on same train
- Pzr Low Level @ 17%
- Overcurrent
- Both trains of Supply Breakers closed
- Load Con
What is the interlock associated with the Pzr Cycling Htrs? Why?
Can’t close both feeder breakers (Protects EDGs from overloading)
Which PORVs provide Cold Overpressure protection? Which pressure instruments are used?
- NRV-152 controlled by NPS-122 (Loop 1 WR)
- NRV-153 controlled by NPS-121 (Loop 2 WR)
What are the Pzr backup Heater trips?
- Loadshed on same train
- Pzr Low Level at 17%
- Overcurrent
What are the important pressure setpoints for the Pzr?
2735# - Max Limit 2485# - Safeties Open 2385# - Rx Trip 2335# - PORVS open 2235# - Normal Ops 2200# - DNB 1950# - Rx Trip 1910# - P11 Block 1775# - SI
What can happen if Channel III (NPP-153) is controlling channel for Pzr # Ctrl and it fails low?
All Pzr PORVs will be Inoperable and the only protection for Overpressure on the Pzr will be the safeties
Where does the PRT drain to?
RCDT pump Suction
With the unit at 100% power, Pressurizer level channel NLP-151 is selected for control and fails LOW. Assuming no operator action, what is the plant response?
Letdown isolates, charging flow increases, seal flow increases, actual level increases, and VCT level decreases.
- Reactor Power 97 percent
- RCS pressure 2260#
- PRZ level channel select switch in position 1 (Channel 3 control, Channel 2 bistable)
- PRZ level 53 percent
- PRZ level recorder select switch in position 1 (Channel 1)
- PRZ liquid level transmitter NLP-152 (Channel 2) fails low
WHAT is the immediate effect on the plant?
Recorder indicates level = level Ref., charging flow is unchanged, all heaters are off, all orifice isolation valves shut, QRV-111 shut