Important Primary Shit Flashcards

1
Q

What is a support function of the SFP system?

A

Used to clean up RWST

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the lowest the SFP can be drained?

A

Suction lines are only 19.5” below surface

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Will cross tying the SFP system thru purification piping prevent boiling?

A

No, only delay it

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is a function of containment?

A

Provides Biological shielding

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the purpose of the divider barrier seal?

A

Prevents flow of steam and air from bypassing the ice condenser

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What are the suction sources for the CEQ Fan?

A

SG Enclosures

PZR Doghouse

CLV Fan Rms

Instrument Rm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What happens on a lo-lo glycol expansion tank level?

A

Expansion tank outlet valves VSO-20/21 close

CIVs VCR-10/20 Close (outside containment)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the flowpath thru the Ice Condenser?

A

1 psf opens lower inlet doors

turning vanes to bottom of baskets

thru intermediate and top deck doors to upper ctmt

condensed by CTS and goes back to lower thru cavity drains

condensed steam/melted ice drains to lower volume

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the function of the containment spray system?

A

Limits post accidend PRESSURE and TEMP

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the purpose of NAOH in the CTS system?

A

Makes Recirc Sump pH between 7-10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Why do the SAT outlet valves and educator sypply valves close on a lo-lo SAT level alarm?

A

Prevents gas binding the pump with nitrogen

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What happens if both Unit 1 aux exhaust fans are lost?

A

12-RRV-306 closes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What are the AES Fan suction sources?

A
CTS Hx
RHR Hx
SI Pump
RHR Pump
CCP and PDP 
CTS Pump
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What must we do when working in the SFP / moving fuel?

A

Manually place AFX in charcoal filter mode.

Still get a signal on High Rad

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Purpose of the Core Barrel

A

primary support

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Purpose of the Thermal Shield

A

protect from neutron embrittlement

some preheating

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Purpose of the core support casting

A

prevents movement of core barrel by fitting in keyways

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Purpose of the diffuser plate

A

provides uniform flow to lower core plate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Purpose of the lower core plate

A

has 4 holes and directs flow thru each assembly

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Purpose of the core baffle / former

A

maintains rectangular fuel assemblies in circular pattern

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Primary source of neutrons for core

A

spontaneous fission of Californium 252

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Secondary source of neutrons for core

A

beryllium activated by gamma

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

What is the flowpath of water in the vessel?

A

enters thru 4 nozzles

98.5% down bw core barrel and vessel wall
1% leaks by to outlet nozzles
.5% to upper head

flow bw thermal shield and barrel for cooling

97% up thru support casting, diffuser plate and lower core plate
.5% bw barrel and baffles
2.5% up control rod guide thimbles

coolant mixes in upper internals and exits outlet nozzles

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Which RVLIS correlation is used when filling and venting RCS with RCP bump method?

A

Upper Plenum

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Narrow Range RVLIS is used when?
NO RCPs
26
Wide Range RVLIS is used when?
WITH RCPs
27
Upper Plenum RVLIS is used when?
NO RCPs
28
What are the Leakage Limits for the RCS?
NO pressure boundary 0.8 (1.0) gpm Unidentified 10 gpm Identified 150 gpd for 1 SG
29
What is RCS Leak Detection required to detect?
1 gpm leak within 4 hours
30
What does the Orifice on the Rx Vessel Head vent do?
prevents leakage greater than capacity of 1 CCP
31
Why is RVLIS pressure used for the subcooling meter?
It's outside containment
32
What RCS penetration is not into the flow path?
RHR Suction from Loop 2 Hot Leg
33
What penetrations are in the RCS flowpath
Wide and Narrow Range RTDs PZR Spray Lines RCS Sampling
34
Which loop does not have midloop indication?
Loop 1
35
What loops are the PZR Spray Lines on?
3 and 4 cold leg
36
Which loop is the RHR Suction on?
2 Hot Leg
37
What loop is the PZR Surge line on?
Loop 3
38
What loops are RVLIS on?
Loop 1 and 3 Hot Legs
39
What loops are Sample lines on in the RCS?
Loops 1 and 3 Hot Legs
40
Which loops are WR Pressure on?
1 and 2 Hot Legs
41
Which loop is normal LD on?
Loop 4 intermediate leg
42
What are the interlocks for starting a RCP?
Bearing lift pump motor starter closed Bearing Lift Oil Pressure 510#
43
What is the purpose of the RCP Flywheel?
Helps remove decay heat immediately after a trip
44
What are the RCP Seal Return flowpaths?
#1 - SW Hx to CCP Suction #2 - RCP Standpipe to RCDT #3 to outlet of RCDT
45
What is the RCP Seal injection flopath?
5 gpm down RCP shaft into RCS 3 gpm thru #1 3 gph thru #2 100 cc/day #3
46
What happens to seal return if VCT level goes up to 70%?
pressure rises also. Seal return flow goes down. Must vent VCT to get it back
47
What will give you a Refueling water sequence?
BOTH QLC-451 AND 452 at 2.5%
48
When using emergency borating, what must be done to the BAT pump?
manually shifted to FAST speed
49
Where does alternate dilution go in automatic?
TOP and BOTTOM of VCT
50
What instrument feeds into the East CCP ELO?
NPP-151
51
What instrument feeds into the West CCP ELO?
NPP-153
52
What must you do on a LOOP regarding the seal return system and why?
Close seal return iso valve QCM-350 to prevent steam binding CCP
53
What is the normal temperature, level and pressure of the PRT?
100*F 83% 3#
54
What instruments are used for Cold Overpressure?
NRV-152 is controlled by NPS-122 (Loop 1 WR) NRV-153 is controlled by NPS-121 (Loop 2 WR)
55
How many acoustic monitors for the PZR Safeties?
1 for each safety
56
How many acoustic monitors for the PZR PORVs?
1 total for all 3 PORVs
57
What is the gallon per percent for the VCT?
19 gal / %
58
What is the gallon per percent for the PZR?
75 gal / %
59
What is built into the pressurizer master level controller to protect the RCP Seals?
Stop on QRV-251 to prevent isolating seal injection. ~47 gpm
60
What is the peak clad temperature for ECCS Acceptance Criteria?
< 2200*F
61
What is the max clad oxidation for ECCS Acceptance Criteria?
< 17%
62
What is the maximum hypotetical Hydrogen Generation for ECCS Acceptance Criteria?
< 1%
63
When do we go on Cold Leg Recirc?
manually aligned when RWST lowers to 20%.
64
What is the suction source for cold leg recirc?
RHR suction is aligned to the Recirculation Sump. RHR provides suction to CCPs and SI pps in addition to the RCS.
65
When do we go on Hot Leg Injection?
5.5 - 7.5 hours after LOCA. Not before 5.5 hrs to avoid core uncovery due to boil off Not after 7.5 to prevent boron precipitation in the reactor
66
What do you have to do before using RHR Spray?
have to close RHR loop injection valves before aligning spray (prevents runout)
67
Where do we take suction from for RHR Spray?
Recirculation Sump
68
How long must we wait to use RHR Spray and why?
> 50 minutes after accident allows for adequate heat removal to have occurred and CCP and SI for decay heat removal
69
Where does RHR tap into CVCS?
Before the LD Hx
70
How do we protect the RHR pump from runout when going to spray?
Close RHR Loop injection valves first
71
How do we protect the RHR pump from runout when going to hot leg recirc?
Cold leg isolation valve closed first, then hot leg is open.
72
While in HOT SBY with all RCPs running, The RC loop flow indicators for RCP #11 all fail LOW with the pump still operating. The probable cause of the total loss of flow indication would be a failure of the associated:
Outside Flow Tap
73
Which ONE of the following is a function of the Rx Vessel Head Vent System?
Removes non-condensable gas or steam from the Rx vessel head under accident conditions.
74
What conditions must be satisfied to start a RCP?
DP across No 1 seal is greater than 215 psig
75
During refueling, the divider barrier and missile blocks separating RC and refueling cavity are removed. As a result, higher flow rates in the containment purge exhaust system will:
Prevent the formation of vapor clouds on the water
76
What are the ECCS Pumps order of Injection with Normal Injection Pressures?
CCP - 2300# SI - 1600# Accumulators - 600# RHR - 200#
77
On a LB LOCA, what would the expected flowrate be of your pumps if pressures were met for injecting? (runout flows)
CCP- 550 gpm SI - 600 gpm RHR - 4500 gpm
78
What is the design basis for Rods?
Maintains Tavg within 5*F of program and restores Tavg within 1*F of program following: 1. 10% step load change 2. 5% / min ramped load change 3. 50% step load change (10% rods)
79
What is the output of the Rod Drive MG set?
260 VAC
80
What are the inputs to Rod Control?
Auctioneered High Tave Auctioneered High PRNI MPC-253, Turbine 1st Stage Impulse Pressure
81
What does the SCD Power Cabinet feed into?
S/D Banks CD
82
What does the 1AC Power Cabinet feed into?
Control Banks AC and S/D Bank A
83
What does the 1BD Power Cabinet feed into?
Control Banks BD and S/D Bank B
84
What does the 2AC Power Cabinet feed into?
Control Banks AC and S/D Bank A
85
What does the 2BD Power Cabinet feed into?
Control Banks BD and S/D Bank B
86
Explain how the Stationary, Movable and Lift Coils work together for outward Rod Motion
Stationary Full Current Moveable Gripper On Stationary Off Lift Coil On Stationary Full On Moveable Gripper Off Lift Coil Off Stationary Half Current
87
Explain how the Stationary, Movable and Lift Coils work together for inward Rod Motion
Stationary Full Current Lift Coil On Movable Gripper On Stationary Off Lift Coil Off Stationary On Moveable Off Stationary Half Current
88
When will you get bank overlap?
Bank Selector Switch in Auto or Manual
89
How much overlap does bank overlap provide?
100 step overlap | 2 banks moving together for 100 steps
90
What are the Rod Control Power Cabinet Urgent Failures?
``` Logic Error Regulation Failure Phase Failure Multiplexing Error Card Removed ```
91
If you have an Urgent Failure on the Rod Logic Cabinet, which Rods are affected?
ALL Rods
92
If you have an Urgent Failure on the Rod Power Cabinet, which Rods are affected?
Rods in groups for that cabinet
93
What does the Variable Gain Unit do in Rod Control?
Increases the output at low power Given reactivity change at low power has a smaller effect on power than at high power
94
What does the Rod Control Mismatch Rate Comparator do?
Compares rate of change bw Turbine 1st Stage Pressure and NIs Provides faster response to transients
95
What is the Rod Speed for the S/D Banks?
62 spm
96
What does indication read for rod speed in auto for S/D Banks C and D in Auto
No Indication (0)
97
How fast do rods move in Manual?
48 SPM
98
How fast do rods move in Auto?
8-72 SPM
99
When to control rods begin moving?
+/- 1.5*F difference between Tavg and Tref
100
When do rods move 8 spm?
1.5-3*F temperature error
101
When do rods stop moving?
1*F temperature error
102
What will give you a NON-URGENT FAILURE on the rod power cabinet?
Loss of redundant power to power or logic cabinet | POWER IS NON-URGENT
103
During a power ascension, w reactor power at 48%, control bank C group 1 rod B-8 drops. Prior to the drop, it was at 228 steps. While restoring the rod, a control rod urgent failure alarm occurs. Why?
urgent failure will be generated in the other bank of rods in that power cabinet due to all lift coil disconnect switches open for that entire group