Pump Panel Companion Flashcards
TASK FORCE 1 3/4”
100 PSI
170 GPM
35 PSI PER 100’
ELKHART SM-30 1 3/4”
85 PSI
190 GPM
45 PSI PER 100’
TASK FORCE ON 2 1/2”
100 PSI
250 GPM
12.5 PSI PER 100’
ELKHART SM-30 ON 2 1/2”
100 PSI
300 GPM
18 PSI PER 100’
15/16” ON 1 3/4”
50 PSI
180 GPM
40 PSI PER 100’
1” ON 1 3/4”
50 PSI
200 GPM
50 PSI PER 100’
1” ON 2 1/2”
50 PSI
200 GPM
8 PSI PER 100’
1 1/8” ON 2 1/2”
50 PSI
250 GPM
12.5 PSI PER 100’
1 1/4” ON 2 1/2”
50 PSI
325 GPM
21 PSI PER 100’
MS 1 1/4”
80 PSI
400 GPM
8 PSI 2 1/2”
1 PSI 5”
MS 1 3/8”
80 PSI
500 GPM
12.5 PSI 2.5”
2 PSI 5”
MS 1 1/2”
80 PSI
600 GPM
18 PSI FOR 2.5”
3 PSI FOR 5”
MS 1 3/4”
80 PSI
800 GPM
32 PSI FOR 2.5”
5 PSI FOR 5”
MS 2”
80 PSI
1000 GPM
50 PSI FOR 2.5”
8 PSI FOR 5”
SINGLE HOSE COEFFICIENTS
1" 150 1 3/4: 12 2 1/2: 2 3: 0.8 4: 0.2 5: .08
DROP 100 / 2
FOR 1 3/4”
TAKE GPM AND DIVIDE BY 100
RESULT /2 IS FL PER 100’
Drop 10
FOR 2 1/2” Take GPM flowing Divide by 100 Subtract 10 If >300, add back first digit Result is friction loss for 100’
CQ^2L
C-HOSE COEFFICIENT
Q-GPM/100
L-HOSE LENGTH/100
MS FOG
100 or 80 PSI
1000 GPM
50 PSI FOR 2.5”
8 PSI FOR 5”
DISTRIBUTOR NOZZLE ON 2 1/2”
100 PSI
400 GPM
32 PSI PER 100’
DISTRIBUTOR NOZZLE ON 1 3/4”
100 PSI
200 GPM
50 PSI PER 100’
WYE / SIAMESE
10 PSI >350 GPM
For Siamese take the average hose length (total feet / number of lines)
MULTIVERSAL
25 PSI
STANDPIPE
25 PSI
AERIAL MANIFOLD
25 PSI
ELEVATION
EP=Height (in ft) x 0.5
EP = 5 psi x number of floors -1
5 PSI PER FLOOR OR 10’
DON’T COUNT FIRST FLOOR
SUPPORT SPRINKLERS
SET PDP TO 150 PSI
STANDARD 1/2” HEAD FLOWS 20 GPM AT 15 PSI
ONE 1000 GPM PUMPER CAN FLOW 50 HEADS
NOZZLE DISCHARGE RATE
GPM=29.7 X D^2 X SQRT NP
D=HOSE DIAMETER
NP=NOZZLE PRESSURE IN PSI
NOZZLE REACTION SOLID STREAM
NR = 1.57 X D^2 X NP
D=NOZZLE DIAMETER IN INCHES
NP NOZZLE PRESSURE IN PSI
NOZZLE REACTION FOG STREAM
NR = 0.0505 X Q X SQRT NP
Q=GPM
NP=NOZZLE PRESSURE IN PSI
NOZZLE REACTION SOLID STREAM (FIELD)
Q/3
Q=GPM
RELAY PUMPING
EITHER MAX DISTANCE OR CONSTANT PRESSURE (MAX VOLUME)
MAXIMUM DISTANCE
2,050’ FOR 5” HOSE
PDP IS 185 FOR 4” 5” (200 FOR 2.5” 3”)
DIVIDE TOTAL LENGTH BY 2,050 ADD PUMPER FOR REMAINDER
CONSTANT PRESSURE
750’ SECTIONS FOR 5” HOSE
PDP IS 175
GIVES YOU 1607 GPM
MILE
5,280’
Hand method 1 3/4”
100=1x12 125=2x9 150=3x9 175=4x9 200=5x9 Good for 150 and above
Hand method 2 1/2”
100=1x1x2 200=2x2x2 300=3x3x2 400=4x4x2 500=5x5x2
Bumper line
Elkhart: 85 psi
Hose: 45 psi
130 total
Front cross lay
Elkhart: 85 psi
Hose: 90 psi
175 total
Rear cross lay
15/16: 50 psi
Hose: 100 psi
150 total
Deck gun
Nozzle: 80
Appliance: 25
105 total
Rear 2.5” pre-connect
Elkhart: 100 psi
Hose: 45
145 total
Rear 1 3/4” pre-connect
Elkhart: 85 psi
Hose: 112.5
197 total
LIKE VOLUMES
0-10%: 3
11-15%: 2
16-25%: 1
MAINTAIN 20 PSI OR MORE AT INTAKE
ENGINE PRESSURE/PUMP DISCHARGE PRESSURE
EP/PDP=NP+THFL+AL+EP NOZZLE PRESSURE TOTAL HOSE FRICTION LOSS APPLIANCE LOSS ELEVATION GAIN/LOSS
STANDPIPE
ALWAYS CALCULATE, 150 PSI IS JUST FOR SPRINKLERS
IF PRV CALCULATE BASED ON TOTAL HEIGHT OF THE STANDPIPE
DROP 10 METHOD VS CQ2L
SAME FROM 160 TO 300 PSI
Like Volumes First Digit Method
Static: 90; Residual 70 Take first digit of static (9) times multipliers 1 x 9 = 9 2 x 9 = 18 3 x 9 = 27 Compare change (20 psi) 0-9 is 1 like volume 10-18 is 2 like volumes 19-27 is 3
Booster line
Elkhart 3F
Min: 50 psi gives you 5 gpm, FL of 0.5 psi per 100’, 51 PDP. MINNIE mouse has the booster at the lowest because she’s weak. She uses the LACE of her skirt to make a LAW badge to look official.
Max: 115 psi gives you 65 gpm, FL of 65 psi per 100’, 245 PDP. the robot MAXIMILLION has the highest because he’s strong. He TIES minnie’s TAIL to a JAIL cell so he can take over. NOAH ROLLS two rhino’s like bowling balls to bash the jail and set her free.
Mod: 100 psi gives you 35 gpm, FL of 18 psi per 100’, 135 PDP. Dieter the MOD tries to make peace by offering DAISIES to minnie and MAIL to max becasue he’s a dumb robot. Max TIES the MAIL to Dieter who gets stuck to the jail again.
LDH pressure rating
Tested at 200 psi equals 185 operating psi
Condensed Q
Field method for 5”
(also 3 and 4”)
Q^2 / 15 = FL per 100’
Connecting to an FDC
You can break the plastic but if you hit the bolts horizontally, they should break right off which is cleaner.
Connect a hose to every input on the FDC manifold.
If swivel is frozen: 1) twist your hose the opposite way a bunch of times before connecting; 2) get a double male and double female from the rig
If clogged with trash or completely broken just go inside and connect to the FDC on the first floor (unless PRV, then it won’t work).
Hydrants
Class C - Red - > 500 GPM
Class B - Orange - 500 - 999 GPM
Class A - Green - 1,000-1,499 GPM
Class AA - Light Blue - 1,500 GPM or greater
The more important metric is intake pressure. That’s what dictates how many lines you can pull.
Water dept can boost pressure or gpm