Private Dwellings Flashcards
- In structures with more than one story, the interior stairs to the cellar will usually be located (a or b)
- With semi attached structures or those with minimal space on one side they will usually be located (a or b)
A. Under the main stair
B. Near the side or rear entrance
1-a over 1 story main stair
2-b semi front or rear ent
It is common to find a closet where the stairs were once located
From a firefighting and fire protection standpoint, what is the major weakness in a PD?
An open unenclosed stairway
In this type of PD the roof of the front porch allows for easy access to upper floor bedrooms.
A. Cape style house
B. Straight line colonial
C. Queen Anne
D. Ranch
B
There are two type of cape style houses, A frame and wide line.
- _______will have a rear entrance and may have two window dormers that are normally found facing the street.
- _______has a front entrance and usually a side entrance with a stoop
- Wide line
2. A frame
What will a single offset window on the second floor indicate on a straight line colonial?
Can this window be used for veis?
The top of the interior stairs leading to the 2nd floor
Should not be used for veis
The presence of dormers usually increases the likelihood of 2nd floor bedrooms. The easiest access to these rooms via portable ladders would be through windows found on________.
A. The dormers
B. Rear
C. Attic
D. Exp 2 & 4 sides
D
Portable laddering of these dormers can be very difficult
The absence of a window in the peak of a PD may indicate________.
A flat roof
In a lightweight construction PD a ladder co uses the pulldown stairs to access the attic to check for extension from a minor smoke condition due to an overheated wire. Do you agree or disagree with this action?
Disagree
These are lightweight stairs and should not be used for attic access or line advancement.
At a PD fire, when should the hose line should be flaked out charged and bled?
Prior to entering the BUILDING
In a PD fire on the 1st or upper floors the primary consideration in access for the first line should be_______.
A. Main entrance
B. Entrance that provides the quickest access
A. Main
In a PD cellar fire primary consideration for access of the first hose line should be_________.
A. Main entrance
B. Entrance that provides the quickest access
B quickest
At a PD fire the status of the interior cellar door should always be checked and communicated to the IC.
T/F
True
The decision to reposition the first hose line (cellar fire in a PD) that was stretched thru a main entrance to a secondary entrance can only be made by a chief off not an acting chief.
T/F
False
Can only be made by a chief OR acting chief
At a PD cellar fire the IC/chief decides to back the first line out the main entrance (1st floor) and operate thru a secondary entrance. Who will work with the eng co to facilitate the advancement into the secondary entrance?
A. 1st and 2nd due LCCs
B. Outside team
C. FE team operating on upper floors
D. FE team operating on 1st floor
D
When line is to be withdrawn to access a cellar fire from a secondary entrance,
Lad co members operating on 1st floor MUST be withdrawn before first line is repositioned from that floor.
In a cellar fire in a PD where should the 1st line be stretched?
Entrance with quickest access to ext fire
In a PD cellar fire where is the 2nd line initially positioned?
A. Into a secondary entrance
B. As per IC
C. Outside building as BU for 1st
D. Floors above
C
If not needed can repositioned for other choices
PD fire 1st floor: after size up where will the first line be stretched?
Through the main entrance door on the 1st floor to extinguish the fire.
Before committing the 1st line members should ensure it didn’t start in the basement. (During initial size up)
1st floor PD fire or upper floor:
The second hose line will be positioned and charged where?
Outside the fire building as BU for the 1st
If not needed– cellar, other floors, exposures
At PD fires on the first or upper floors: Whenever two hose lines are stretched and operating, a third hoseline will be positioned and charged at the front of the building and operated as ordered by the IC
T/F
True
PD upper floor fire:
After size up, where should the 1st line be stretched?
Thru the main entrance to upper floor in order to extinguish the fire.
During the initial size up at apparent upper floor fires members should ensure they check to determine it didn’t start on a lower floor or cellar before committing the first line
PD fire: If more than one occupant is found on an upper floor, the IC shall ensure that adequate staffing is assigned to effect their removal. The primary function of the engine company during this critical period should be to:
A. Continue operating the line
B. Reposition the line to the upper floor
C. Protect the interior stairs
D. Await instruction from the IC
C protect int stair
To determine if a PD is balloon frame construction remove a baseboard on an exterior wall and check for the presence of a _________.
If ________is not found should the building be treated as balloon frame?
Sole plate
None found—-treat as balloon
Sole plate and a top plate on each floor is platform construction
Roof vent on flat roof PDs is a general area of responsibility of:
1st ladder
2nd ladder
1st
At a flat roof PD who ensures ventilation of the roof?
1st ladder
2nd ladder
2nd
At a peaked roof PD if roof ventilation is needed, who is responsible for it?
1st ladder
2nd ladder
2nd
At a PD fire who is responsible for shutting down the utilities?
1st ladder
2nd ladder
2nd
At a fire in a peaked roof PD the 1st truck officer should if manpower and conditions permit have members conduct an examination of the cellar to determine if the fire started at this location. Who should he contact if unable to cover this area?
2nd arriving ladder co
The positions tools and duties of the officer can and FE FFs are the same for portable aerial and TL ops at a peaked roof PD fire.
T/F
True