Powerplant and APU Quiz Flashcards

1
Q

Takeoff can be done using what power settings

A

FLEX/MCT and TO/GA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

You have not inserted a FLEX temp. Can you still takeoff?

A

Yes, but only using TO/GA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Only a single ignitor is displayed during the first engine start. Is this normal?

A

Yes, the FADEC alternates ignitors for engine start

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the range for A/THR operation?

A

Between Idle and CLB

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

After takeoff, the A/THR will not become active until…

A

The thrust levers are placed in the CLB position

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

An Amber REV indication means what?

Green?

A

Reversers are unlocked

Reversers are fully deployed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How do you energize the FADEC

A

Turn the engine mode selector to IGN/START

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

An amber Fault light on the ENG Master panel comes on during engine start. This indicates…

A

The automatic start sequence has been aborted

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

During a manual start you select a ENG Master switch to ON. What are you looking for?

A

Fuel Used is reset
Both Igniters are powered
Fuel Flow is indicated

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What function does the FADEC carry out during a manual start?

A

Passive monitoring of the start sequence

Close the start valve and cut off the ignition on the ground

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The gray background on N2 disappears at 58% during a start sequence. What does this indicate?

A

The start sequence is completed and engine parameters have stabilized

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is the simplest way to bring the APU back on line after a shutdown?

A

Provided AVAIL is illuminated on the start button, simply push the APU Master Switch back to ON

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

If the APU Fire Button is pressed, what kind of shut down will be initiated?

A

APU EMER shut down

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

How long may the APU be operated with a LOW OIL LEVEL advisory?

A

Up to 10 Hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly