Power Plant Flashcards
Normal APU start source is in the battery position. True or False.
TRUE (QRH - Normal procedures )
During the ground start the autostart system will abort the start for
Hung start, Hot start, No EGT rise
During an inflight flameout, the EEC will make a maximum of 3 start attempts then reset. True or False
TRUE
APU can be started on the ground and will operate upto a maximum of ___.
20,000ft (7.30.1)
APU provides pneumatic pressure for 1 pack up to a maximum of
15,000ft (7.30.1)
EGT indications are inhibited from changing color to amber for____minutes during T/O or Go around when reach continuous limit.
5 min (7.20.2)
Oil pressure and Temperature indication will turn____when reaching caution limits and return to____when limits are within normal limits.
AMBER/ WHITE (7.20.2)
Oil quantity indications will change to___if quantity is low.
Magenta (7.20.3)
EEC uses__inputs to set___ thrust.
Thrust lever, forward and reverse (7.20.5)
EEC Alternate mode provides thrust limiting at maximum N1 or maximum EPR whenever thrust lever is less than full forward position. True or False
FALSE (7.20.6)
When the EEC transfer from normal to alternate the autothrottle will
The autothrottle disconnects. (7.20.7)