POC BES Flashcards

1
Q

WHAT IS THE REGIONAL ENTITY?

A

WECC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

HOW MANY AREAS DOES WECC COVER?

A

5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

XFRMR’S OPERATE ON WHAT PRINCIPLE?

A

ELECTROMAGNETIC INDUCTION

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

OHMS LAW

A

E=IXR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

HOW TO DEFINE POWER FACTOR

A

RATIO OF REAL POWER TO APPARENT POWER

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

WHICH PART OF A GENERATOR IS STATIONARY?

A

STATOR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

DEFINE EFFICIENCY

A

THE MEASURE OF HOW OUTPUT IS RECEIVED FOR A GIVEN AMOUNT OF INPUT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

HEAT RATE MEASUREMENT?

A

BTU’S

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

UNIT CAPABILITY

A

MAX.- SAFE GENERATION PRODUCTION
MIN.-SMALLEST AMOUNT OF GENERATION THAT A UNIT CAN SUSTAIN

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

RESPONSE RATE IS MEASURED IN WHAT?

A

MW/MIN.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

HOW TO CLASSIFY A SUBSTATION?

A

THEY HAVE XFRMR’S

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

WHAT IS THE DIFFERENCE BETWEEN REACTOR AND CAPACITORS

A

REACTORS- SINK VARS
CAPACITORS-SOURCE VARS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

FAULT RECORDERS DO WHAT?

A

LOG ON PAPER OR COMPUTER CRITICAL CURRENT AND VOLTAGE WAVEFORMS AT THE TIME OF ANY FAULT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

WHICH SIDE OF A XFMR IS THE PRIMARY?

A

THE WINDINGS ELECTRICALLY CONNECTED TO THE POWER SOURCE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

HOW TO FIND TURNS RATIO?

A

V1/V2=N1/N2
(CROSS MULTIPLY)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

STEP UP XFMR REFERS TO?

A

VOLTAGE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

CAN A XFMR PRODUCE POWER?

A

NO

18
Q

XFMR POWER LOSSES?

A

HYSTERESIS, EDDY CURRENTS, I2R (HEAT)

19
Q

WHICH XFMR HAS PHASE SHIFT?

A

DELTA-WYE
WYE-DELTA

20
Q

WHICH XFMR DOESNT HAVE PHASE SHIFT?

A

WYE-WYE
DELTA-DELTA

21
Q

WHAT DEFINES A POWER XFMR?

A

VOLTAGES HIGHER THAN 69kV

22
Q

WHAT IS A AUTO XFMR?

A

A SINGLE WINDING XFMR WITH A TERMINAL THAT DIVIDES THE WINDINGS IN TWO

23
Q

WHAT IS A PHASE SHIFTING XFMR?

A

CONTROL POWER FLOW OVER PARALLEL LINES BY ADJUSTING VOLTAGE PHASE ANGLE AT ONE END OF THE LINE

24
Q

WHAT IS A INSTRUMENT XFMR?

A

CT’S LOWERS CURRENT OR PT’S LOWER VOLTAGE FOR RELAY CONTROL CIRCUITRY

25
Q

WHICH CHARACTERISTICS DESCRIBE BES REQUIREMENTS?

A

100kV AND ABOVE
GENERATION LARGER THAN 20MVA OR GENERATION AGGREGATE CAPACITY GREATER THAN 75MVA

26
Q

DOES ALUMINUM OR COPPER HAVE LOWER RESISTANCE

A

COPPER

27
Q

WHAT IS CHARGING CURRENT?

A

CURRENT THAT FLOWS DUE TO THE ALTERNATE CHARGE AND DISCHARGE OF THE LINE DUE TO ALTERNATING VOLTAGE REGARDLESS OF WHETHER THE CIRCUIT IS CLOSED OR OPEN-ENDED

28
Q

DURING LIGHT LOAD WHERE IS VOLTAGE HIGHER?

A

AT THE RECEIVING END

29
Q

SERIES CAPACITORS DUE WHAT?

A

DECREASE IMPEDANCE AND INDUCTIVE REACTANCE
INCREASE POWER

30
Q

LIST 4 SOURCES OF REACTIVE POWER

A

OVER EXCITED GENERATOR AN SYNCHRONOUS CONDENSORS
SHUNT CAPACITORS
LINE CAPACITANCE

31
Q

IS A BIRD ON A LINE A COMMON FAULT?

A

NO

32
Q

ARE INTERNAL FAULTS INSIDE?

A

YES

33
Q

DISTANCE RELAY

A

ONLY ANSWER WITH DISTANCE IN THE CHOICE

34
Q

LIST 3 TRIPS FOR PILOT SCHEMES

A

TRANSFER TRIPPING,
DIRECTIONAL COMPARISON,
PHASE COMPARISON

35
Q

3 THINGS PROTECTED BY DIFFERENTIAL PROTECTION

A

GENERATORS, XFMRS,BUS SECTIONS

36
Q

WHAT DIFFERENTIAL ARE CT’S LOOKING FOR?

A

CURRENT

37
Q

RAS

A

ALL OF THE ABOVE

38
Q

OVERGENERATING DOES WHAT TO FREQ.?

A

RAISES IT

39
Q

WHAT ARE UNSCHEDULED FLOWS

A

LOOP, PARALLEL, AND INADVERTENT FLOWS

40
Q

WHAT DOES AGC DO?

A

-AUTO ADJUSTS GENERATION
-COMPUTER CONTROL TO MAINTAIN LOAD/GEN BALANCE
-USES AN ERROR SIGNAL CALL AREA CONTROL ERROR TO FUNCTION

41
Q

MODES OF AGC?

A

TIE LINE BIAS CONTROL,
FLAT FREQ. CONTROL,
FLAT TIE LINE CONTROL