PNEUMATIC SYSTEM Flashcards
With engines and APU running and APU bleed valve selected ON, select the correct
statement:
a. Engine bleed valves open, X bleed valve opens, APU bleed valve closes
b. Engine bleed valves close, X bleed valve opens, APU bleed valve opens
c. Engine bleed valves open, X bleed valve closes, APU bleed valve opens
d. Engine bleed valves close, X bleed valve closes, APU bleed valve opens
b. Engine bleed valves close, X bleed valve opens, APU bleed valve opens
To provide external air for ENG start the following switching is required:
a. Pneumatic X-bleed AUTO
b. Pneumatic X-bleed OPEN
c. Engine bleed switches OFF
d. APU bleed switch OFF
b. Pneumatic X-bleed OPEN
Air bleed from the engines is:
a. not cooled prior to being used by the systems
b. cooled in a heat exchanger by cooling air bleed from fan section
c. cooled using ambient air
d. only cooled in air conditioning part
b. cooled in a heat exchanger by cooling air bleed from fan section
High pressure air is supplied from:
a. Engine 1 and 2 bleed systems, APU load compressor, HP ground connection
b. Engine 1 and 2 bleed systems
c. Engine 1 and 2 bleed systems and APU load compressor
a. Engine 1 and 2 bleed systems, APU load compressor, HP ground connection
Pneumatic system operation is controlled and monitored by:
a. one bleed monitoring computer
b. two bleed valve computers
c. two bleed monitoring computers
c. two bleed monitoring computers
Which source operates the bleed valve?
a. Pneumatic
b. Electric
c. Both
a. Pneumatic
What happens when pressure and temperature are not sufficient to supply the
corresponding engine bleed valve:
a. IP valve closed
b. HP valve opened, IP stage closed
c. HP valve opened, IP stage remains in the same configuration
c. HP valve opened, IP stage remains in the same configuration
Can you control the HP valve position through the air bleed cockpit panel?
a. Yes
b. No
b. No
If the bleed valve closes, the HP valve:
a. opens automatically
b. closes automatically
b. closes automatically
Temperature regulation is achieved by the precooler which regulates and limits the
temperature at:
a. 150ºC
b. 85ºC
c. 200ºC
c. 200ºC
Which source controls the crossbleed valve:
a. Pneumatic
b. Electric
b. Electric
Cross-bleed valve is provided with 2 electrical motors:
a. one for the automatic mode, the other one for the manual mode
b. two for the automatic mode
c. two for the manual mode
a. one for the automatic mode, the other one for the manual mode
In case of low upstream pressure, the high pressure valve (HP valve) is:
a. pneumatically closed
b. open
c. electrically opened
d. electrically closed
a. pneumatically closed