AIRCONDITIONING - PRESSURIZATION Flashcards
What appens when the Hot air “FAULT” light illuminates on the air conditioning panel?
the hot air press reg. valve closes and the trim air valves close
What happens in case of an Air Conditioning System Controller dual lane failure
The related Pack is lost, and the hot air pressure regulating valve and associated trim air valves closes.
During normal flight the Avionics Ventilation System controls the temperature of the cooling air by:
passing air through a skin heat exchanger
When is the RAM AIR switch used?
Only when delta P is less than 1psi
What happens when there is an Air Conditioning System Controller single lane failure:
no effect, as the second lane takes over.
Each Pack is consist of heat exchangers, compressor and turbine. The purpose of the turbine is to:
- Drives the compressor
- Serves as Cooling Air Fan
- Expands and cools the air.
True or False?
The Mixer Unit connects to the ff:
- cabin fans,
- LP ground connector,
- emergency ram air inlet,
- Pack 1 and Pack 2.
True
What happens when the Hot air press reg. valve fails to open?
no effect
Bleed air supplied from the APU (APU bleed valve open), the pack flow is automatically selected to what value?
High
How does the Trim Air Valve optimize the temperature?
adding hot air
What is the function of the Hot air pressure regulating valve?
Regulates the pressure of hot air, tapped upstream of the packs
How does the Pack flow control valve operate? and how is it controlled?
- pneumatically operated
- electrically controlled
The temperature selectors are located in:
the cockpit overhead panel
Pack flow may be selected from the?
cockpit overhead panel
Engine flow demand, when the heating or cooling demand in one zone cannot be satisfied:
the minimum idle is increased automatically
What is the maximum norm cabin altitude?
8000 ft
What is the maximum negative differential pressure for the cabin:
-1 psi
Is it possible to use simultaneously Packs and LP Ground Unit during long stops in a hot airfield:
NO
Trim air valves are modulated by the?
air conditioning system controllers
The mixing unit is connected to the:
- packs,
- cabin air,
- emergency ram air inlet
- LP ground connector
Once set to “ON”, how does the air conditioning packs operate?
automatically and independently of each other
If the Emergency ram air inlet is set to “ON”, what are the 2 conditions for the ram air valve to open?
- when delta P < 1 psi
- and the Ditching pb is not selected
Hot-Air Pressure-Regulating Valve is controlled by the:
Air Conditioning System Controller 1