PFT Reported data Flashcards
Reported data for FVC?
Report largest FVC and FEV1
- biggest 2 c/in 150ml of each other
Reported data for FVLs?
Report largest FVC and FEV1
- biggest 2 c/in 150ml of each other
- same as FVC
Reported data for slow vital capacities (SVCs and ICs)
Report largest SVC -> diff b/w 2 largest <150
- 3 good tests
- Report mean of largest 3 for IC (within 150 of each other) -> confirm later
Reported data for PEF
3 good tests -> 2 largest c/in 0.67 L/S (FVL) or 40 lpm
Reported data for MVV
Predicted = MVV/ [40xFEV1]
- for 12 sec max vent
- report RR and MV (highest)
- Variability <20@ b/w min 2 acceptable
Reported data for Pleth
mean value of 3 good tests with <5% variability
- Report (largest-smallest)/Mean
- Raw & SGaw -> effort should be within 10% of each other
Reported data for nitrogen washout?
Breath until N2 < 1.5% for >3 breaths
- 1 test -> if >1
- <10% variability and reported mean
Reported data for Helium Dilution?
One good test if >1 <10% variability and report mean
- Corrected to BTPS
Reported data for DLCO
2 acceptable within 3ml or 10% of highest reported mean
- 4 min b/w tests (10 min if emphysema)
How do you calculate reversibility?
% improve = (pre-post)/pre x 100
- > 12% and >200ml increase in FEV1 or FVC (significant)
How is Body Plethysmography reported?
Report mean of 3 (within 5%) => (largest-smallest)/mean
- SGaw and Raw shoudl be within 10% of acceptable
Determining repeatability of Pleth
largest FRC - smallest FRC / mean
Reported data for MIP and MEP?
Max MIP and MEP reported
PEF reported data?
Largest PEF reported