Oxygen Flashcards
Which component of the oxygen system is located outside the pressure vessel?
The 115 ft³ Oxygen bottle is located exterior of the aft pressure vessel.
How many different types of oxygen mask are in the aircraft?
2 - Diluter Demand Pilot-type and Constant Flow Passenger-type.
Where is the First Aid Mask located?
In the aft of the aircraft in the air stair area.
Should the oxygen system be charged if flight above 12,000 PA is not anticipated?
Yes, The system should be charged prior to every flight.
What position on the pilot’s oxygen mask should be used during smoke and fume elimination?
Emergency
Is any action required to initiate oxygen flow if the passenger mask deploy?
Yes, The passenger must pull the mask to extract the lanyard pin from the valve to start the flow of oxygen.
What is the highest recommended cabin altitude for sustained flight while using the Oxygen System?
25,000 feet
What is the Time of Useful Conciences (TUC) at FL250?
3-5 Minutes, Unless rapid decompression in which the time could be cut in half.