Oxygen Flashcards

1
Q

3 Methods to read PSI information?

A

Electronic
- ECAM/EICAS
-External Filling Connection

Analog
- Direct Reading Pressure Gauge

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is frangible disc?

A

It is an indication when there’s an overpressure in oxygen bottles and we need to check each bottle gauge to know which bottle causes to discharge the disc

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

When is REGUL LO PR indication shows
on ECAM/EICAS?

A

Appears incase of oxygen low pressure (50 PSI) detected on the low pressure circuit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When is microphone ready to use in the
flight crew oxygen mask?

A

A pressure switch connected to the
supply valve allows the microphone to be used while the oxygen system is in use

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What are the three operating modes of
Diluter Demand Regulator?

A

Normal, 100% Oxygen, and Emergency

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Who send the signal of Lo PSI to the Lo PSI Manifold?

A

Pressure S/W on the Lo PSI Manifold

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What does Yellow Indicator mean?

A

It indicates if the Frangible Disc fractures

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

100% mode means?

A

Only 100% pure oxygen is supplied to the flight crew oxygen masks

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Where is the Crew Oxygen Cylinders located?

A

Either on the Avionics Compartment or FWD Cargo Compartment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Where is the Passenger Oxygen Cylinders located?

A

Aft Cargo Compartment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Two ways to activate the oxygen masks?

A

Either by pushing the Mask Man On
S/W manually or automatically deployment when 14.000 ft cabin altitude is reached

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Purpose of the Voltage Averaging Unit (VAU)?

A

It is used to gather more than one pressure information when there’s multiple oxygen bottles to show their average PSI to the EICAS (Status Page) or ECAM (Door/Oxy Page)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Stowage boxes of Chemical Oxygen Supply system?

A

Emergency Oxygen Containers (EOC)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Stowage boxes of Gaseous Oxygen Supply system?

A

Passenger Service Unit (PSU)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What component is added to the Gaseous type oxygen supply system?

A

Flow Control Unit (FCU)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is the purpose of FCU?

A

Pressure Regulator and produces over pressure to open the PSU doors then the masks will deploy

17
Q

Does the Passenger Oxygen System have its own Yellow Indicator?

A

Yes