The “clean water inlet” and “clean water outlet” found in an OWS are ______ valves
Solenoid
Oil Content Detector of an OWS employs an _________ system based on the principles of light scattering.
optical
Vacuum Gravity and __________ are the two basic types of OWS.
Pressure
RO elements should be cleaned when the TDS level of the _______ _______ exceeds 500 ppm.
product water
During start-up, do not ______ 950 psi system pressure or 4.35 gpm product water flow.
exceed
In _________ Mode, product flow should be in the 0.9 to 1.0 gpm range.
Polishing
DO NOT operate the _____ ______ pump while system is in backwash mode.
High Pressure
When renewing the 5 and 20 micron filters, ensure that the high pressure _____ reads 0 psi before maintenance.
gauge
A likely cause of unacceptable effluent from the ______ Stage Separator is filter element not sealed properly.
Second
Never exceed 1000psi on the _____ Gauge.
High Pressure