Other Analyses Flashcards

1
Q

What is Dimethyl sulphide (DMS)?

A

An important, and sometimes unwanted, beer flavour compound

DMS is often measured using a gas spectrometer.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How is free malt DMS measured?

A

By incubating milled malt in a tube at 35˚C for 30 min and analyzing the headspace

This analysis focuses on the area above the malt.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

How is total malt DMS measured?

A

By degrading the precursor SMM to DMS using a caustic solution and incubating at 50˚C

SMM values are calculated by subtracting free DMS from total DMS.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the recommended level of DMS/SMM in malt specifications?

A

Set to provide the target level of DMS in the beer after brewing

For most beers, this value is below its flavour threshold.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is viscosity?

A

The resistance of a fluid to a change in shape

High viscosities can cause problems in wort separation, whirlpool operations, and beer filtration.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How is viscosity measured?

A

Using a viscometer, which measures the time taken for a set volume to flow through a capillary

Results are expressed in units of centipoise (cP).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What are the ideal viscosity values for brewing?

A

Values should be below 1.60 cP; results lower than 1.5 cP are even better

Viscosity is sometimes reported in mPa.s (milliPascal.seconds) on analysis sheets.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the significance of β-glucan in malt?

A

It causes problems in wort separation and beer filtration

The amount depends on levels in barley and the degree of modification.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How is β-glucan analyzed?

A

Using flow injection analysis with calcofluor that fluoresces when binding to β-glucan

The concentration is calculated from the fluorescence measured.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What are the ideal β-glucan levels in malt?

A

Should ideally be below 150 mg/L; many breweries set the limit at 100 mg/L

High levels can hinder brewing efficiency.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the Wort Attenuation Limit (WAL)?

A

A test to determine how fermentable a wort is

It helps assess the reduction in gravity or extract in the wort by yeast.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What does the term ‘attenuate’ mean in brewing?

A

To make thin or weak, referring to the reduction in gravity or extract in the wort by yeast

This is key for understanding fermentation processes.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

How is the WAL test performed?

A

Wort is added to a flask with yeast and kept warm to allow the yeast to consume sugar

The test is complete when the gravity of the wort ceases to fall.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the formula for calculating percentage apparent attenuation?

A

Percentage apparent attenuation = (OG - PG) / OG x 100

OG = original gravity; PG = attenuation limit test gravity.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What does the term ‘real attenuation’ account for?

A

It accounts for the difference in gravity caused by the increase in ethanol

It is calculated as % real attenuation = % apparent attenuation x 0.819.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

If a congress wort has an OG of 11°P and a WAL gravity of 1.2°P, what is the percentage apparent attenuation?

A

89.09%

Calculated as (11 - 1.2) / 11 x 100.

17
Q

What is the relationship between percentage fermentability and percentage attenuation?

A

They are the same; both describe how fermentable the wort made from malt is

The same calculations are used for both metrics.