Oral Bank - FIRE PROTECTION & DETECTION Flashcards

1
Q

How many ENGINE fire extinguishers are provided?

A

2 on each wing (4 total)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

FIRE CARGO FWD: Pressing FWD cargo fire ARM switch causes what actions? (4)

A
  • Two packs shut off
  • Arms lower cargo compartment fire extinguishers
  • Configures equip cooling to override mode. Turns off all airflow and heat into lower cargo compartments
  • closes master trim air valve
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

How many fire extinguisher bottles are provided for the forward and aft lower cargo compartments?

A

4 bottles (2 bottles discharge immediately, 2 bottles discharge after delay)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How many APU fire bottles are provided?

A

1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What action discharges the APU fire extinguisher?

A

Rotating the APU fire switch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Can you shut down the APU from outside the A/C?

A

Yes, APU fire protection panel in right body gear well

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Is there smoke detection provided for the crew rest area?

A

Yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What happens when you push the CARGO FIRE Depressurisation Switch with the MAIN deck fire switch ARMED?

A

Initiates A/C depressurisation (main deck fire suppression, 2 packs off, equip cooling closed loop and shuts off airflow, closes master trim air valve)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What unlocks an engine fire switch? (3)

A
  • Fire warning
  • Fuel control switch CUTOFF
  • Pushing the fire override switch
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Is the engine fire/overheat detection system a single or dual loop system?

A

Dual loop

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What does arming the FWD CARGO fire switch do on the Passenger A/C? (4)

A
  • Arms cargo fire extinguishers
  • Equip cooling into override mode and airflow and heat turns off to FWD compartment
  • Turns off pack 3
  • Turns off nitrogen generation system
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

How many fire extinguisher bottles are provided for fire fighting in the FWD and AFT cargo compartments on the 747-8 A/C?

A

6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly