Oral Bank - ELECTRICAL Flashcards

1
Q

What are the main AC electrical power sources on the LCF? (2)

A
  • Four IDG’s
  • Two external power sources
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the main function of the Standby Power Switch in the Auto position?

A

Allows the main and APU standby busses to be powered from available sources

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What does the “AVAIL” light indicate on the External and APU PWR switches?

A

The related power source is PLUGGED IN and available and the power quality is ACCEPTABLE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When is the main cargo deck handling bus powered?

A

When the “AVAIL” light is displayed on the APU 2 or EXT 2 switches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What electrical power source provides power for the lower lobe cargo handling, fuel panel, and AUX 4 hydraulic pump?

A

EXT PWR 1 or APU GEN 1 is AVAIL or selected ON (powering the Ground Handling bus)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What are some of the equipment items powered but he Utility busses?

A
  • 5 fuel pumps
  • Galley equipment
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What happens when you push a Generator Drive Disconnect (DRIVE DISC) switch? (2)

A
  • Disconnects the IDG from engine when above idle speed
  • Opens the relate Generator Control Breaker (GCB)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What condition would automatically disconnect the IDG if not manually disconnected by the flight crew?

A

Excessively high drive oil temperature

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What does a Bus Isolation (ISLN) light illuminated indicate? (2)

A
  • BTB open
  • AC bus isolated from synchronous bus
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

How do you reconnect an IDG that has been disconnected?

A

IDG cannot be restored by flight crew - maintenance required

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

How is the electrical system configured during an automatic ILS approach?

A

AC and DC busses 1, 2 and 3 are isolated from the sync bus. AC bus 4 continues to power the sync bus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What are the main AC electrical power sources?

A
  • Four IDG’s
  • Two APU generators
  • Two external power sources
How well did you know this?
1
Not at all
2
3
4
5
Perfectly