ON WATCH KNOWLEDGE Flashcards
What’s the SR’s and officers on watch ?
DLC•OOD•DSO-PTW’s•
DPO-Welfare,rounds,discipline
HQ1/DCOA-manages incident board , mag keys, stability plots
DMESR1/2- Shiphaz key holders
Duty APC - manages HV spaces and distribution
DWESR- WE kit , small mags and relays containment info during an incident
DAVSR- hanger / flight deck , hanger sentry
LET Reactions to general alarms
HPSW RM Pressure
HPAC stop
Crash stop vent
Account for ET manpower
Isolations for L’s, mechs, Vent
Fuel tanks supply/ditch
Responsibility on watch
Accountable to DMESR, primary role is to be I/C of the main group
Supervise on watch ETs to ensure ‘ES’ are maintained
Ensure rounds / watch handovers are conducted correctly
Conduct rounds during middle watch
Responsibility on watch
Accountable to DMESR, primary role is to be I/C of the main group
Supervise on watch ETs to ensure ‘ES’ are maintained
Ensure rounds / watch handovers are conducted correctly
Conduct rounds during middle watch
What’s LOA ?
A form issued and cancelled by duty APC
What does LOA do
It defines the limits & nature of work, that may be carried out in the vicinity of HV
What does the person In charge (PIC) has to be for his name to be on the LOA
HV Competent(HVCP)
What stability issues needed to be considered?
Fire fighting
Flooding
Tank rotations
Fw filling
Gw
Drain downs
What’s a ISO certificate
A form given to a CP by APC to make known which HV apparatus is isolated
What’s a switching schedule?
A form of consent raised by APC & issued by APC to do isolation on equipment
What’s a SFT
Sanction for test - signed by APC then given to a HV CP PIC , in charge of testing HV equipment
I/C FCP for FIRE
Go to scene of incident
Ensure effective and controlled attack on fire
Be de-brief by person who discovered the fire
Establish forward control point
Supervise hose running - minimum 220ft for MMS / Galley
Ensure correct ‘FF’ equipment is used , establish foam dump
Brief support party - where,type fire , hazard
Keep HQ1 informed of progress/ developments
I/C FCP for flood
Look for EL’s supplies that need isolation
Is it contaminated?
Pump it , with salvage educator, weda pump,bilge pump
Permission to isolate VV
If not (pipe clamps ,wedges ,shorting or alternative iso