What can be the size of COCKLOFT in?
Taxpayers? 3.2
Brownstones?2.2.18
Rowframes?5.2.2
H Type? 5.9.9 (I)
Taxpayers- 4 inches to MORE than 6ft
Brownstones- 2ft to 3ft
Rowframes- 1ft to tall enough for a man to stand in
H Type- as much as 4 ft
Hi Pressure Pumping Engines 9 Add 1
What FLOOR does HI PRESSURE pumping begin?
31
Numbers
Taxpayers 4.4.1 (F)
What % of space is needed for a room or fire area to contain, the EXPLOSIVE MIXTURE for an entire area to possibly explode?
25%
Numbers
What SIZE hole for vertical ventilation on a TAXPAYER?
8ft x 8ft
where possible
Numbers
Under River Rails 2.7.1
2 1/2 inch OUTLETS are LOCATED_____ throughout under river tubes?
Section VALVES are approximately ____ apart?
200 FEET
600 FEET (valves 6 letters)
Numbers
Taxpayers 3.3.3
In how long may UNPROTECTED OPEN WEB STEEL JOISTS be vulnerable to COLLAPSE from elevated temp from a fire?
5 to 10 mins
Numbers
Taxpayers 3.6.1
How LONG would a 50 ft I-BEAM extend when heated?
How LONG would a 100ft I-BEAM extend when heated
4 inches-50ft beam
9 1/2 inches-100ft beam
Numbers
Collapse Add 2. 2.1
How big are the SEARCH MARKING at COLLAPSE operations?
2’x2’
NO SQUARE around the X
Numbers
AUC 349 PPF 7.2
What is the proper placement of PPF fans?
4ft to 6ft AWAY from the ATTACK STAIRWELL DOOR
on the GROUND FLOOR
80 degree tilt
Numbers
EP Gas
The EXPLOSIVE range of gas depending on the mixture?
5%-15%
Numbers
The maximum range from SCBA to PAC-TRACKER
900 ft
within LINE OF SIGHT
Steam in generating plants temps can be as high as 900 degrees
Numbers
Saws TB 9 3.3.2
When would a CARBIDE blade be put O.O.S?
- 8 or MORE tips BROKEN/MISSING
- WORN DOWN to the circumference of the blade
Numbers
Saws TB 9 3.3.3
How worn down of the blade to put the ALUMINUM OXIDE or SILICON CARBIDE O.O.S?
8” in diameter or LESS
Numbers
AUC 149
How many turns to shut the valve off to the BUCKEYE PIPELINE?
42 FULL TURNS
84 HALF TURNS
42D PRIMARY UTAC channel
Numbers
TB Purple K handheld extinguisher
Discharge Time?
Discharge Range?
Coverage approximately?
Time-11 Seconds
Range- 19 to 20 ft
Coverage-30 square ft
Numbers
AUC 207 add 9. 3.2.4
What is the minimum distance when applying water to CATENARY WIRES from a FOG NOZZLE?
10 ft
Numbers
How far away are DEPT apparatus are placed from a BUCKEYE pipeline leak?
Extinguishing a fire in a truck containing LP gas everyone not engaged should be kept at least how many FEET from:
Front and rear?
Sides?
Buckeye 600 ft
LP GAS
1000 ft FRONT and REAR
500 ft from SIDES
Numbers
Buckeye Pipeline
Flag person are ——ft on each side of an —— if ADJACENT to —-?
1000 ft
INCIDENT
RAILROAD TRACKS
Numbers
Altair
+++ would indicate?
XXX would indicate?
O2 is ABOVE 30%
LEL is ABOVE 100%
Numbers
TB Apparatus C2 add1
What speed may the apparatus not exceed with SNOW CHAINS on?
Must NOT EXCEED 30mph
Numbers
Rope 2
A member FREE FALLING how far would be considered a sufficient impact load to place the LIFE BELT O.O.S?
3 FT or MORE
Waterproof connections are good for use up to 3FT of water
TB 4
Numbers
Ropes
Size n LENGTHS
LSR?
UTILITY ROPE?
SEARCH ROPE?
UTILITY CORD?
PSS rope?
LSR-9/16”-150ft
Utility Rope-9/16”-50 ft
Search Rope-5/16”or 7.5mm-200ft
Utility Cord-1/4”-25ft
PSS-7.5mm-50ft
Numbers
How many members are needed to start a tour to operate as a SOC SUPPORT LADDER?
1 Boss(trained) 3 Trained FF
4 trained members ALL TOGETHER
Numbers
Circle of Danger
When using CHAINSAW?
When using PORTABLE SAW?
Chainsaw-RADIUS at LEAST 10 ft
Portable Saw-Radius at LEAST 20 ft