NUMBERS Flashcards
Numbers
What can be the size of COCKLOFT in?
Taxpayers? 3.2
Brownstones?2.2.18
Rowframes?5.2.2
H Type? 5.9.9 (I)
Taxpayers- 4 inches to MORE than 6ft
Brownstones- 2ft to 3ft
Rowframes- 1ft to tall enough for a man to stand in
H Type- as much as 4 ft
Hi Pressure Pumping Engines 9 Add 1
What FLOOR does HI PRESSURE pumping begin?
31
Numbers
Taxpayers 4.4.1 (F)
What % of space is needed for a room or fire area to contain, the EXPLOSIVE MIXTURE for an entire area to possibly explode?
25%
Numbers
What SIZE hole for vertical ventilation on a TAXPAYER?
8ft x 8ft
where possible
Numbers
Under River Rails 2.7.1
2 1/2 inch OUTLETS are LOCATED_____ throughout under river tubes?
Section VALVES are approximately ____ apart?
200 FEET
600 FEET (valves 6 letters)
Numbers
Taxpayers 3.3.3
In how long may UNPROTECTED OPEN WEB STEEL JOISTS be vulnerable to COLLAPSE from elevated temp from a fire?
5 to 10 mins
Numbers
Taxpayers 3.6.1
How LONG would a 50 ft I-BEAM extend when heated?
How LONG would a 100ft I-BEAM extend when heated
4 inches-50ft beam
9 1/2 inches-100ft beam
Numbers
Collapse Add 2. 2.1
How big are the SEARCH MARKING at COLLAPSE operations?
2’x2’
NO SQUARE around the X
Numbers
AUC 349 PPF 7.2
What is the proper placement of PPF fans?
4ft to 6ft AWAY from the ATTACK STAIRWELL DOOR
on the GROUND FLOOR
80 degree tilt
Numbers
EP Gas
The EXPLOSIVE range of gas depending on the mixture?
5%-15%
Numbers
The maximum range from SCBA to PAC-TRACKER
900 ft
within LINE OF SIGHT
Steam in generating plants temps can be as high as 900 degrees
Numbers
Saws TB 9 3.3.2
When would a CARBIDE blade be put O.O.S?
- 8 or MORE tips BROKEN/MISSING
- WORN DOWN to the circumference of the blade
Numbers
Saws TB 9 3.3.3
How worn down of the blade to put the ALUMINUM OXIDE or SILICON CARBIDE O.O.S?
8” in diameter or LESS
Numbers
AUC 149
How many turns to shut the valve off to the BUCKEYE PIPELINE?
42 FULL TURNS
84 HALF TURNS
42D PRIMARY UTAC channel
Numbers
TB Purple K handheld extinguisher
Discharge Time?
Discharge Range?
Coverage approximately?
Time-11 Seconds
Range- 19 to 20 ft
Coverage-30 square ft
Numbers
AUC 207 add 9. 3.2.4
What is the minimum distance when applying water to CATENARY WIRES from a FOG NOZZLE?
10 ft
Numbers
How far away are DEPT apparatus are placed from a BUCKEYE pipeline leak?
Extinguishing a fire in a truck containing LP gas everyone not engaged should be kept at least how many FEET from:
Front and rear?
Sides?
Buckeye 600 ft
LP GAS
1000 ft FRONT and REAR
500 ft from SIDES
Numbers
Buckeye Pipeline
Flag person are ——ft on each side of an —— if ADJACENT to —-?
1000 ft
INCIDENT
RAILROAD TRACKS
Numbers
Altair
+++ would indicate?
XXX would indicate?
O2 is ABOVE 30%
LEL is ABOVE 100%
Numbers
TB Apparatus C2 add1
What speed may the apparatus not exceed with SNOW CHAINS on?
Must NOT EXCEED 30mph
Numbers
Rope 2
A member FREE FALLING how far would be considered a sufficient impact load to place the LIFE BELT O.O.S?
3 FT or MORE
Waterproof connections are good for use up to 3FT of water
TB 4
Numbers
Ropes
Size n LENGTHS
LSR?
UTILITY ROPE?
SEARCH ROPE?
UTILITY CORD?
PSS rope?
LSR-9/16”-150ft
Utility Rope-9/16”-50 ft
Search Rope-5/16”or 7.5mm-200ft
Utility Cord-1/4”-25ft
PSS-7.5mm-50ft
Numbers
How many members are needed to start a tour to operate as a SOC SUPPORT LADDER?
1 Boss(trained) 3 Trained FF
4 trained members ALL TOGETHER
Numbers
Circle of Danger
When using CHAINSAW?
When using PORTABLE SAW?
Chainsaw-RADIUS at LEAST 10 ft
Portable Saw-Radius at LEAST 20 ft
Numbers
TB SCBA 3.2.8
The VIBRALERT and HUD will alarm when how much percentage approximately remains in the cylinder?
25% approximately
Numbers
Engine Ops Chptr 5 5.6.9
A SINGLE 90 degree kink in an 1 3/4 handline can result in a loss of how many gallons per minute?
20 gpm or MORE
Numbers
Engine Chptr 10 10.3.10
When supplying a SPRINKLER system,discharge pressure should start at how many PSI?
150 PSI
STANDPIPE system floors 1-10 supplied at 150 psi also
Numbers
Gas SENSIT detector
The SENSIT can detect when a gas source as low as —— ppm of ——- is detected?
20 ppm
Methane
Numbers
UltraRadiac ERP Add 4D
Low RATE alarm
High RATE alarm
Low DOSE alarm
High DOSE alarm
Low RATE alarm-2mR/hr
High RATE alarm-50R/hr
Low DOSE alarm-5R
High DOSE alarm-12R
Numbers
Extrication N Disentanglement 14.4
The rule we observe that,AIRBAGS are LIVE at an extrications or disentanglement are?
5” from SIDE
10” from DRIVER
20”from PASSENGER
Numbers
What are considered Safe ATMOSPHERIC Conditions at Confined Space Rescues?
-O2 between 19.5% n 23.5%
LEL- NOT OVER 10%
CO- NOT OVER 35 ppm
Hydrogen Sulfide-NOT OVER 10 ppm
Numbers
PSS TB Rope 4
How much rope is pulled through the EXO to ensure PSS is properly functioning?
3 to 6 inches
Numbers
Regs Chptr 11 11.1.17
When turning CORNERS no apparatus should be driven in excess
of —— mph?
15 mph
4” reducer 15mph (speed hump)
3” reducer 20 mph (speed hump)
Numbers
Regs 11 11.3.25
When responding to COMMAND POST members will be at least how many FEET from away?
25 ft
Officer goes to Post alone
Numbers
Company Journal
What pages are used for:
Chief Visit
Drills
Mask Cylinders
pg 500-498 Chief visits
pg 497-495 Drills
pg 494 Mask cylinders(Battalion Depots)
Numbers
Multiple Dwellings
SCISSOR STAIR exit doors are placed no less than -—- apart in the public hallway?
No less than 15’ apart
Numbers
COCKLOFT size:
Brownstones?
Rowframes?
2 to 3 FT
1FT to TALL enough to stand in
Numbers
Engine 6 6.2.3
DRESSER hydrant will provide — to — discharge greater than the SMITH?
10% to 15% MORE
Numbers
Engine Chpt 9 add 1
HIGH pressure PUMPING is defined as operating pressure at?
OVER 250 psi
Numbers
Regulations Chptr 13
How much time does a Company have to procure the meal?
45 mins in the 1st due RESPONSE area
Numbers
Haz Mat 4
UEL of Carbon Monoxide
LEL of Carbon Monoxide
UEL=74%
LEL=12.5%
Numbers
TB Tools 1
Pressurized Water Extinguisher:
Gallons?
Weight?
Water expelled?
Psi?
2 1/2 gallons
30 lbs
55 seconds
100psi
Numbers
Comm 13 ARCS
The DUPLEX H/T channels are:
Channel
11
12
14-Primary Subway
15- Secondary Subway
Numbers
Comm 13 ARCS
What channels are the REVERSE CHANNELS on the POST RADIO or the mobile UHF RADIO
Reverse Channel/Repeater Channel
17-11
18-12
19-14
20-15
Numbers
Taxpayers 8.1.20
The BASKET of a TL can be positioned how far above the street in order to operate the stream into a store?
1 to 2 feet ABOVE street level
Same as Search Rope 1 to 2 Feet above ground level
Numbers Building Code Classification Class 1 Class 2 Class 3 Class 4 Class 5 Class 6
Class 1- FIREPROOF
Class 2- FIRE PROTECTED
Class 3- NON Fire Proof
Class 4- WOOD
Class 5-METAL
Class 6-TIMBER
Numbers
Private Dwelling Chptr 6 1.6
Collapse in TRADITIONAL PD can occur within?
Collapse in TRADITIONAL PD with no ceiling can occur within?
Collapse in LIGHTWEIGHT PD can occur within?
- an hour
- within 20 mins (no ceiling)
- within 5-10 mins (LW)
Numbers
TB 1 Elevator Emergency 3.7.2
What size planks are used as a bridge for a side exit removal in an elevator emergency?
Planks 6’ FEET or LONGER
Numbers Tower Ladders 1.1 (7th bullet) What’s the clearance for the outriggers for a: 75ft TL? 95ft TL?
How many members operate in the bucket?
75 ft TL- 6 ft
95 ft TL-6ft 8inches
2 members in BUCKET
Numbers
TB Elevators 7.3.2
In a SINGLE car BLIND hoistway,emergency access opening shall be provided at EVERY —floor,but not more than —-feet apart?
3rd FLOOR
Not more than 36 FEET apart
Numbers
TB Elevators 7.3.3
If emergency SIDE DOOR is provided it must be within how many FEET of an ADJACENT car side door when attempting EMERGENCY REMOVAL?
Within 3 FEET
Numbers
TB 31 4.3.2
Sound Powered Telephone CONNECTORS in underriver tubes are found approximately how many feet apart?
200 ft apart
Same as STANDPIPE OUTLETS
Numbers
TB 37 Floor Jack
Maximum WEIGHT can lift?
Maximum HEIGHT raised to?
2 tons
3 1/2 to 18 INCHES
4000lbs
Numbers
Haz Mat 18
How do we administer NARCAN to an
ADULT patient?
Pediatric patient?
Spray 4mg/0.1ml in ONE NOSTRIL Wait 2-3 mins (minimal response) Spray In OTHER NOSTRIL 4mg/0.1ml
Numbers
Eng Chptr 9 add 2
AIR PRESSURIZED STANDPIPE
An alarm will sound when pressure RISES above ——psi?
AIR PRESSURE in the AIR RELEASE VALVES shall be released in no more than?
- Alarm will sound w/ pressure ABOVE 25 psi
- no more than 3 MINUTES
Numbers
Comm Chptr 2 2.6.1
Each UNIT shall maintain how many SPARE ROLLS of TELEPRINTER PAPER and where is it located?
- At least 2 SPARE ROLLS
- COMPANY office
Numbers
TB Emergency 3 8.2
How far away are we operating a HANDLINE from downed wires?
25 FEET (at least) FOG NOZZLE used
Numbers
Comm Chptr 14 add 4
What are the primary and secondary UTAC channels used in the NY region?
Primary
UTAC channel 42D
(Zone B Channel 10)
Secondary
UTAC channel 41D
Numbers
Comm Chptr 11 3.5.1
In order to reset EA the button may be depressed for how long?
2 seconds
Numbers
Comm 11 3.5
How long do we depress button for:
PTT?
EAB?
Reset EAB?
HT flashlight?
PTT-1/2 sec
EAB-1 sec
Reset EAB-2sec
HT Flashlight -2sec
Numbers
Eng 11
Large Caliber Streams is any stream that flows ——gpm?
300 gpm
Numbers
In order to be CFR, how many FF must be CFR Trained to start the tour?
2 trained FF’s to START TOUR
*if during tour 1 CFR member goes sick, and OFFICER is CFR,
COMPANY shall remain available for CFR
1 Officer/1FF
Numbers
AUC 200 Winter Ops
Where a building involved is —- than —- stories preference shall be given to —— company to enter the block first?
Higher than 3 stories
Ladder company enters 1st
Engine will handstretch
Numbers
Eng 6 6.7.1
What color hydrant is on a —- inch diameter or greater main and is excellent for FD use?
RED AIR COCK HYDRANT
30 inch main
red SATELLITE water system Hydrant
Engine Company AVOID these👆
Numbers
Eng 6 6.7.1
How many turns to FULLY TURN ON, some hydrants, that are closed year round located on parkways n expressways?
18 turns CLOCKWISE
Yellow hydrants
Numbers
Private Dwelling Chptr 6
Areas unsupported by columns w/ spans GREATER than —ft are generally an indication that lightweight construction has been used?
25 feet
Numbers
Private Dwellings Chptr 6 4.2.4
When the spacing between lightweight floor supports is —— apart, the potential exists for a larger opening to be formed for members to fall thru?
24 inches
Numbers
Hi Rise Office 4.1
1968 building code for Fire pumps?
1938 building code for Fire pumps?
1968 OVER 300ft
1938 OVER 250ft
Numbers
SB 56
A CD-19 report shall be forward by apparatus operator/officer within —- of the apparatus collision/incident?
4 days
96 hours
MV-104
Within 10 days to DMV
Numbers
Foam 7.2
Three Engines n Two Ladders should provide —- containers of foam for a total of —- gallons of AR-AFFF foam concentrate?
13 five gallon containers
65 total gallons
This will provide approximately 17 minutes of finished
firefighting foam at 3%
Numbers
Hi Rise Office
3rd Stage pumping is REQUIRED when pressures exceed?
3rd Stage pumping is PREFERRED at pressures over?
600 psi (Floors 101-110) required
500 psi (Floors 81-90) preferred
Numbers
Emg Scaffolds
AUC 207 Light Train
How often for progress reports when using a Light Train?
How long do you let an overheated hoist motor cool before the WORKER resets the button?
15 minutes
Numbers
How many turns from the STREET to shutoff hydrant?
What turn would you see a significant decrease in water flow?
1712
17 turns Counterclockwise
12 turns a significant decrease in water flow
Numbers
Comm Chptr 11 Handi Talkie’s
When receiving a SPARE H/T which channels MUST be checked for proper ID?
HT-1 TAC 1
HT-2 CMD 1
HT-9 TAC SEC
December ninth
January twenty ninth
Numbers Akron NY Multiversal Nozzle TIPS? PSI? Gallons per minute?
1 1/4 : 100psi
1 1/2 : 70 psi
2 :50psi
No more than 800 gallons per minute
Numbers
TB 37 FLOOR JACK
Max lbs lifted?
Lifting height?
How many pumps?
2 tons
3 1/2 inches to 18 inches
5 pumps
Numbers
COCKLOFT nozzle
Hole needed?
Clearance from TOP of CEILING joists to BOTTOM of ROOF joists?
GPM?
3’x3’ HOLE
4” Clearance
125 GPM
Numbers
ERP ADD 4A Radalert 2.6
FD uses —- as an ACTION LEVEL?
HOTLINE is established at a rate of —-?
1mR/Hr=ACTION LEVEL
2mR/Hr=HOTLINE
Numbers
TB ROPE 1 LSR 4.14
A HOCKLE reduces the strength of the LSR by how much?
40%-50%
Hockle=OOS
Numbers AUC 159 add 7
What is the WEIGHT CAPACITY OR max # people allowed in FLAT BOTTOM BOAT operation?
380 lbs OR 3 people
Numbers
TB PAK TRACKER ADD 8 5.4
Pak Tracker receiver can LOCK onto how many SCBA at a time?
1 SCBA at a time
Numbers
Hazmat 1
How far away are we keeping everyone that is not involved in operation at a LPG tank?
1000 FEET from FRONT/REAR
500 FEET from SIDES
Numbers
Confined Space
What are considered safe Atmospheric conditions at Confined Space responses?
Not over 10% LEL (10.1% is unsafe)
Not over 35 PPM of CO (36ppm is unsafe)
Not over 10 PPM Hydrogen Sulfide (11ppm is unsafe)
O2 between 19.5 n 23.5 (19.4 unsafe) (23.6 unsafe)
Numbers
LOFT 5.1.10
Cast Iron columns can fracture n fail at —— degrees?
Cast Iron loses —-% of its original strength?
1100 degrees
58%
- strength lost is cumulative NEVER regained
- cast iron unable to move will CRACK
Numbers
Comm 11 Chptr 11 add 3
The 2 encrypted channels in the Tactical Zone are?
HT-9/TAC SEC ( Tactical)
HT-10/CMD SEC (Command)
Channels are STRAPPED
Just turn to these channels only action to be done
Monitored on the PORTABLE EFAS
Numbers
AUC 325 add 2 JFK
The discharge pressure when supplying PA/ARFF crash trucks should not exceed?
Crash trucks ONLY carry?
80 psi
Only carries 200FT of 1 3/4 hose
Numbers
AUC 325 add 2 JFK
Hydrant pressure at JFK airport?
H-I-L
H-160 PSI (Y)
I-90 PSI (BY)
L-60 psi (BS)
Numbers
Confined Space
Weight of TL used as an HIGH POINT anchor?
Weight of AL used as a HIGH POINT anchor?
TL 1000 lbs
AL 250 lbs
Numbers AUC 180 add 2 Fire/Ice Operating pressure at the nozzle? Optimal nozzle pressure? Safe STANDOFF distance? MINIMUM safe distance? Stream distance for solution to the manhole opening?
Operating 60-100 psi
Optimal 60-80
Standoff 5O Feet
Minimum 25 Feet
Approximately 1 foot in FRONT of Manhole opening
Numbers
TB 8 (11 c)
To make sure the ignition is off in a HYBRID VEHICLE the KEY FOB is at least —- away from the vehicle?
15 feet away
Voltage Cables ORANGE in MOST hybrid cars, SOME can be BLUE
Numbers
MD 6.6.3
FAST UNIT and CFR Engine will be assigned to — when FIRE in on the —- FLOOR or ABOVE?
Fire Sector
7th floor
Fire on 6th floor or below determined by IC
Numbers
TIC 6000Tools 27 DS 4
How many lights in a row is shown for the Battery/Power indicator?
Each light represents how many minutes of operational time?
4 LEDs in a row
Each light represents 40-45 mins of operational time
Numbers
TIC 6000 Tools27 DS4
LIGHTS/ %/ hours/ of the TIC?
4
3
2
1
1
4 GREEN 75% to 100% 3-31/2 hrs
3 GREEN 50%to 75% 2-3 hrs
2 Yellow 25%to 50% 1-2 hrs
1 Red 0%to 25% less than 1 HOUR
1 RED FLASHING
Low battery
5 mins or less remaining
Numbers TB Tools 36 Digital In Line Gauge “HI-P” indicates? “HI-F”indicates? “LO-F” indicates?
HI-P indicates pressure OVER 200psi (red led)
HI-F indicates water flow OVER 250 gpm (blue led)
LO-F indicates water flow UNDER 80 gpm(blue led)
Numbers
TB Rope 1 DS 4
The landing mat is to be used in rope training operations to a max height of — stories?
3 stories
Numbers
AUC 323 add 2
What month(s) are the training notebooks forwarded for evaluation to the Battalion and Division training coordinator?
13 month n 17 month
Tool list on 1st page
Numbers
TB Elevators (7.3.1) (5.1.1)
In a single car blind hoist way, emergency access openings shall be provided at every —-floor but not more than —- apart?
Fireman Service is required in all elevators that serve —— or travel —- or more?
Every 3rd floor
Not more than 36 FEET apart
Fireman Service required Jan 1st 1980
Elev-serve 3 or more LANDINGS
Elev-travels 25 FEET or MORE
Numbers
EP STEAM 2.2
Steam pressures in generating plants?
Steam pressure in buried supply piping?
PSI # n Temp#?
Plants
Pressure 2000psi
Temp 900 degrees
Piping
Pressure 170psi
Temp 350 degrees
Numbers
Portable Ladders
When performing the leg lock, which leg is placed over n under?
Which rungs?
Locking Leg
over n under
The rung that is
2 rungs ABOVE the one the member is standing on
Numbers
AUC 277
How wide n how high are windows designed to remove non-ambulatory students?
32”WIDE
48” LENGTH
window SILLS painted RED inside n outside
Numbers
ERP add 2
Exposure to chemical agents will result in sign n symptoms in how long:
Choking agents?
Blood agents?
Blister agents?
Nerve agents?
Choking-Immediate
Blood- Immediate
Blister (garlic)
Mustards-hours
Lewisite-minutes
Nerve (fruity)
Vapor-Seconds
Liquids-Minutes to hours
Numbers
TB Tools 9
A carbide tip blade should be placed OOS if there is — or more tips broken on a
12 tooth blade?
3 or more tips
8 or more tips on 24 tooth blade
Numbers AUC 159 (5.2.3)
Units assigned portable dewatering pumps shall ensure that pumps are placed on apparatus ——- hours prior to predicted storm?
48 HOURS
Numbers
If a hoist motor on a scaffold OVER HEATED, how long do we allow it to cool?
In case of contact w/ BLEACH flush skin or eyes w/ water for at least ———? CFR 3 (15.14.1)
15 mins OVER HEATED Motor
15 mins contact w/ BLEACH