GAS Flashcards

1
Q

GAS
Add 2
What are the 2 sensors the ALTAIR is equipped for?

A

GAS
and
OXYGEN

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

GAS
Add 2

How will you know the ALTAIR is operating properly while air monitoring?

A
Vibrate
and 
Flashing GREEN LIGHT 
every 
30 seconds
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

GAS
Add 2

The NORMAL reading on the ALTAIR in FRESH AIR?

A

LEL 0.0%

O2 20.8%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

GAS
Add 2

When will the ALTAIR alarm?

A

LEL 10%

O2 19.5% (oxygen deficient)
02 23.5% ( oxygen enriched)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

GAS
Add 2

A series of XXX under the COMB/EX on the ALTAIR would indicate?

A

atmosphere is

ABOVE 100% LEL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

GAS
Add 2
Three large +++ in the O2 icon on the ALTAIR will indicate?

A

Atmosphere is

ABOVE 30% OXYGEN

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

GAS
Add 2
In which atmosphere would the LEL sensor on the ALTAIR, NOT have accurate reading?

A

Oxygen DEFICIENT atmosphere

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

GAS

What is considered INTRINSICALLY safe to use in a potentially explosive atmosphere?

A
  • Gas Detectors
  • Gas Meters
  • H/T
  • Flashlights (FDNY issued)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Gas

Depending on the mixture the explosive range is?
Gas is Toxic or Non Toxic?

A

5%-15%

Non Toxic

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Gas
EP Nat Gas 5

Indications of a MAJOR GAS EMERGENCY when:
How much LEL is detected

Outside a structure?

Inside a structure?

In an UNVENTED subsurface structure?

A

10% LEL (outside)

10% LEL (inside)

20% LEL (subsurface manhole/sewer)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Gas
EP Natural Gas 5
Gas present in how many subsurface structureS would indicate a Major Gas Emergency?

A

2 or MORE

Manholes,sewer etc

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

EP Gas 4.3

Which Distribution Mains are made of steel,plastic, or if older cast iron?

A

Medium and low pressure mains

High Pressure are made of STEEL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

EP GAS

Which Distribution Mains have control valves?

A

High and Medium pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

EP GAS pg 8
Who’s MAIN VALVES have tags w/ ID number inside the valve cover?

Who’s MAIN VALVES are identified by an ID # stamped on North side of collar?

National Grid or Con Ed

A

Con Ed ID #’s on tags

National Grid ID# stamped on North Side of collar

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

EP GAS 4.4

A “NC” stamped on a tag near the service meter indicates?

An “EFV” stamped on a tag near the service meter indicates?

A

NC indicates NO CURB VALVE or SERVICE VALVE

EFV indicates an excess flow valve
EFV should limit or stop excess flow down pressure from it

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

EP GAS 4.4.1

Which valve if installed on the outside of a building does not require a curb valve or service valve?

A

Exterior Gas Service Valve is present no curb/service valve is required

17
Q

EP GAS 4.4.2
Peck Vents are installed on which type of pressure outputs?
Color of Peck vent?

A

Medium OR High pressure

Red Cap

18
Q

EP Gas 4.4.2

Service Regulators are usually located ——- the gas meter on —— and —- pressure systems?

A

Before
Medium AND High Pressure

*reduces gas to low pressure (1/4 psi)