Multiple Dwellings Flashcards

1
Q

Multiple Dwellings 2.1
OLT
A building with— windows per floor and —— usually indicates railroad flats with —-?

A

4 windows
NO FRONT FIRE ESCAPE
With a REAR FIRE ESCAPE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Multiple Dwellings 1.2
What years were these built:
Old Law Tenements?
New Law Tenements?

A

OLT- BEFORE 4/12/1901

NLT-ON or AFTER 4/12/1901
and BEFORE 4/18/1929

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Multiple Dwellings
OLT

A building w/ 4 windows AND front F/E would usually indicate?

A

3 to 4 apts per floor

With a REAR F/E
USUALLY

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Multiple Dwellings 3.4.6
Who is special called for FIRE on 2 FLOORS of an:
OLT?
NLT?

A

Extra Engine
Extra Truck

No progress in a short time 2nd Alarm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Multiple Dwellings 5.9.9

How far away should a TRENCH CUT be from the INITIAL VENT HOLE?

A

20 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Multiple Dwellings 6.15

2nd due Ladders responsibilities at a HIRIFPMD?

A
  • ENSURE Elevators are recalled/searched
  • SEARCH PUBLIC hallway
  • ENSURE EVAC stairs are CLOSED on FIRE FLOOR
  • SEARCH ATTACK STAIRS 5 floors ABOVE
  • CONTROL WCD if ordered by IC
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Multiple Dwellings 6.15.4/6.16.4
1st due ROOF tools
2nd due ROOF tools
3rd due ROOF tools

A

1st due ROOF
KO CURTAIN
HYDRA RAM
HALLIGAN

2nd due ROOF
ROPE
MAUL
HALLIGAN

3rd due ROOF
KO CURTAIN
NORMAL TOOLS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Multiple Dwellings
LRFPMD 7.8 pg 84
Who bringing the KO curtain for a fire on the 3rd floor of a 5 story low
Rise Fire proof MD?

A

2nd due INSIDE TEAM to the FLOOR ABOVE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Multiple Dwellings
LRFPMD
Who bringing the KO CURTAIN for a TOP FLOOR FIRE at a Low Rise Fire Proof MD?

A

2nd due ROOF

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Multiple Dwellings
LRFPMD

Roof Access at a LRFPMD?
B-E-S-T

A

Building (attached)

ES (enclosed stairway)

T (Trucks AL or TL)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Multiple Dwellings
LRFPMD 7.6 pg 83
When may an ENGINE company Handstretch an 1 3/4 handline at a low rise FP multiple dwelling?

A

Small hallways
w/EVERY APT DOOR that is WITHIN
50 feet of EVERY STAIRWAY

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Multiple Dwellings
LRFPMD 7.2
How many and what type of STAIRWAYS may be encountered in low rise fire proof MD’s?

A

ONE single stairway
or
TWO remote stairway
May be OPEN or ENCLOSED

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Multiple Dwelling 6.18

What are the 5th n 6th due LADDER company’s designated at a HRFPMD?

A

5th-FAST TRUCK

6th-VENTILATION SUPPORT TRUCK

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Multiple Dwellings
HIRIFPMD 6.8.2

WHO obtains the POST RADIO from WHO?

Where is brought?

What channel is link established on?

A
  • 2nd Engine from 1st arriving Battalion
  • where 1st hoseline been connected
  • Command Channel
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Multiple Dwellings
HIRIFPMD 6.11
Who is responsible for placing the High Rise Nozzle into operation?

A

5th ENGINE Company

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Multiple Dwelling
HIRIFPMD 6.14.3
Apartment LETTERS are stenciled where on project building?

A

ON
or
BELOW
THE 1st FLOOR WINDOW SILL

17
Q

Multiple Dwelling
HIRIFPMD 6.14.5 (E)
Who is getting the ROOF and how are they getting there in the NYC project building?

A

1st LCC

Evacuation stairway

18
Q

Multiple Dwellings
HIRIFPMD 6.15

2nd due ladder responsible for
Search-Ensure-Search

A
  • search public hallway (fire floor)
  • ensure EVAC stair doorS closed (fire floor)
  • search ATTACK stairwell 5 floors above fire floor
19
Q

Multiple Dwellings
HIRIFPMD 6.18

The 5th ladder at a HIRIFPMD is?
The 6th ladder at a HIRIFPMD is?

A

5th FAST

6th VENTILATION Support Group

20
Q

Multiple Dwelling 7.4 Note
Where does 1st due ROOF FF go in a:
Low Rise Fireproof?
Hi Rise Fireproof?

A

Low Rise to the ROOF

High Rise to the FLOOR ABOVE

21
Q

Multiple Dwellings (6.14.4) (7.7.1)
Roof FF uses what stairs in a LRFPMD to the ROOF?
Roof FF uses what stairs in a HIRIFPMD to FLOOR ABOVE?

A

LRFPMD-Evacuation stairs to ROOF

HIRIFPMD-Attack stairs to FLOOR ABOVE

22
Q

Multiple Dwelling 7.7.3

What the 1st n 2nd ROOF tool assignment at a LRFPMD?

A

Halligan
Halligan Hook
Life Saving Rope

For BOTH

TOP FLOOR FIRE 2nd due brings KO CURTAIN

23
Q

Multiple Dwellings 8.7 CLASS 2 Buildings

Who chooses the proper standpipe location and best access that will result in a quicker stretch n faster water on Fire?

A

1st ladder AND engine OFFICER(S)

24
Q

Multiple Dwellings add 4

How long will an audible tone sound for when a key Fob is used on the door frame to gain entry into NYCHA?

A

7-9 seconds

25
Multiple Dwelling Low Rise FPMD’s 7.2 Who recalls the elevators at a LOW RISE FP MD?
1st ladder recalls 2nd ladder ensures elevators are recalled n searched IC ensures elevator are recalled, searched n controlled
26
Multiple Dwelling Low Rise FPMD’s 7.7.1 Who will notify who of the attack stairway when two staircases are present in a Low Rise FPMD?
1st Ladder Notifies IC and ENGINE of the Attack stairway
27
Multiple Dwellings Low Rise FDMD’s 7.7.1 What staircase is used by the ROOF man to get to the roof in LRFPMD’s in buildings w/ two staircases? What staircase is used by ROOF man to go FLOOR ABOVE in a HIFPMD?
Low Rise FPMD Roof man uses EVAC stairway to ROOF HIFPMD Roof man useS ATTACK stairway to FLOOR ABOVE
28
Multiple Dwelling Low Rise FPMD 7.7.3 Who gives approval to ventilate the ATTACK stairway at a Low Rise FPMD?
IC gives approval of ventilation of everything except the FIRE APT FIRE APT LADDER OFFICER gives approval
29
Multiple Dwellings 8.6.3 Class 2’s Who will ensure that all members on scene are aware of which entrance door operations are being conducted from?
1st ENGINE and 1st Ladder
30
Multiple Dwellings 8.6.2 Class 2’s If members encounter occupants evacuating from upper floors, where removal is necessary who are they communicating this message too?
IC and 1st LADDER OFFICER
31
Multiple Dwellings 8.6.3 Class 2’s In the event it is determined that another entrance to the apt may provide better access, who would this message be communicated too?
IC FIRE SECTOR SUPERVISOR MEMBERS on FIRE FLOOR MEMBERS on FLOOR ABOVE
32
Multiple Dwelling 8.7 Class 2’s Who will choose proper standpipe location and best access that will result in a quicker stretch and faster water on Fire?
ENGINE Officer And LADDER Officer
33
Multiple Dwelling 8.7 Class 2’s In a CLASS 2 building w/ an open and enclosed stairway which stairway should be used as the attack stairway?
Open stairway-ATTACK stairway Enclosed stairway-EVACUATION stairway for the occupants
34
Multiple Dwellings Class 2’s pg 112 Difference between the type of FIRE STAIRS?
OPEN fire STAIR 2 doors lead directly into apts in SAME WING SHARED fire STAIR 2 doors lead into apts In DIFFERENT WINGS ENCLOSED fire Stair 2 doors lead into VESTIBULE or HALLWAY which lead to apts doors
35
Multiple Dwelling 6.6.3 HIRIFPMD’s Fast Unit and CFR will be assigned to who when the fire is on the 6th floor? Fast Unit and CFR will be assigned to who when fire is on the 7th floor?
6th floor or BELOW assigned to IC 7th floor or ABOVE assigned to FIRE SECTOR
36
Multiple Dwellings? Glossary Fire PARTITIONS have a a fire restive rating of how long as per 1938 Building Code? Fire WALLS ratings 1968 BC? Fire WALL ratings 2008 BC?
Partitions-at least 3 hours Walls 1968 BC- at 4 hours Walls 2008 BC- 2 OR 3 hours depending on occupancy
37
Multiple Dwellings 4.8.8 How many stories are some OLD OLT’s found in the rear of other buildings? What the distance btwn front n rear building? What type of construction?
2-5 stories 10-25 FEET usually Frame or NFP
38
``` Multiple Dwellings (2.3) (2.4) Fireproof partitions in building built in the 1920’s 1930’s 1940’s Go as high as? ```
C-U-T 1920’s CEILING of TOP FLOOR 1930’s UNDERSIDE of ROOFBOARDS 1940’s TOP of ROOFBOARDS
39
Multiple Dwelling LRFPMD 7.8 Who’s bringing KO CURTAIN where in a low rise FPMD?
2nd due inside team FLOOR ABOVE TOP FLOOR FIRE 2nd ROOF brings KO CURTAIN to ROOF