NAVAIR 01-1A-505-1 Flashcards
1
Q
If wire end was not capped, how many inches must be trimmed off?
A
2 inches
2
Q
Solderability of tin-plated copper wire degrades significantly within how many months?
A
6 months to a year after production
3
Q
Wiring minimum clearance from structure, surfaces, and equipment?
A
1/2 inch
4
Q
A minimum clearance between wiring and fluid carrying lines, tubes and equipment shall be what?
A
2 inches
5
Q
Common types of corrosion?
A
Uniform Surface Attack Galvanic (dissimilar metals) Pitting Crevice (concentration cell) Inter-granular Stress Erosion Fretting Corrosion.
6
Q
Shield effectiveness is directly proportional to its what?
A
Thickness
7
Q
Flexible cable bend radius?
A
Not less than 6 times the outside diameter of the cable
8
Q
Semi-rigid cable bend radius?
A
Not less than 10 times the outside diameter of the cable