MX6 iBrid Flashcards
What is the overall measuring range for Carbon Monoxide (CO) sensors?
0 to 10,000 ppm
What is the low range for Carbon Monoxide (CO) sensors?
0 to 999 ppm
What is the high range for Carbon Monoxide (CO) sensors?
999 to 10,000 ppm
What is the measuring range for Oxygen (O2) sensors?
0 to 30%
What is the measuring range for Methane (CH4) sensors?
0 to 5%
What is the low range resolution for Carbon Monoxide (CO) sensors?
1 ppm
What is the resolution for Oxygen (O2) sensors?
0.1%
What is the resolution for Methane (CH4) sensors?
0.01%
What is the low alarm point for Carbon Monoxide (CO) in the MX6 Monitor?
25 ppm
What is the high alarm point for Carbon Monoxide (CO) in the MX6 Monitor?
9999 ppm
What is the low alarm point for Oxygen (O2) in the MX6 Monitor?
19.5%
What is the high alarm point for Oxygen (O2) in the MX6 Monitor?
23.5%
What is the low alarm point for Methane (CH4) in the MX6 Monitor?
1.0%
What is the high alarm point for Methane (CH4) in the MX6 Monitor?
2.5%
Fill in the blank: The low range for Carbon Monoxide (CO) sensors is _______.
0 to 999 ppm
True or False: The resolution for Oxygen (O2) sensors is 0.01%.
False
Fill in the blank: The overall measuring range for Methane (CH4) sensors is _______.
0 to 5%
What is the overall measuring range for Carbon Monoxide (CO) sensors?
0 to 10,000 ppm
This range includes both low and high measuring ranges.
What is the low measuring range for Carbon Monoxide (CO) sensors?
0 to 999 ppm
This range is specifically for detecting lower concentrations of CO.
What is the high measuring range for Carbon Monoxide (CO) sensors?
999 to 10,000 ppm
This range is used for higher concentrations of CO.
What is the resolution for the overall range of Carbon Monoxide (CO) sensors?
1 to 50 ppm
This indicates the smallest change in concentration that can be detected.
What is the resolution for the low range of Carbon Monoxide (CO) sensors?
1 ppm
This allows for precise measurement in lower concentration ranges.
What is the resolution for the high range of Carbon Monoxide (CO) sensors?
50 ppm
This is the smallest detectable change in high concentrations.
What is the measuring range for Oxygen (O2) sensors?
0 to 30%
This range is typical for measuring oxygen levels in various environments.
What is the resolution for Oxygen (O2) sensors?
0.1%
This indicates the precision of the O2 measurement.
What is the measuring range for Methane (CH4) sensors?
0 to 5%
This range is used for detecting methane concentration in the air.
What is the resolution for Methane (CH4) sensors?
0.01%
This allows for very precise measurements of methane levels.
What does CO stand for?
Carbon Monoxide
What does O2 stand for?
Oxygen
What is the low alarm level for Carbon Monoxide (CO)?
25 ppm
What is the low alarm level for Oxygen (O2)?
19.5%
What is the high alarm level for Oxygen (O2)?
23.5%
What does CH4 stand for?
Methane
What is the low alarm level for Methane (CH4)?
1.0%
What is the high alarm level for Methane (CH4)?
2.5%
What is the low alarm level for the Mine Rescue’s MX6 Monitor for CO?
9999 ppm
What is the low alarm level for the Mine Rescue’s MX6 Monitor for Oxygen?
17.5%
What is the high alarm level for the Mine Rescue’s MX6 Monitor for Oxygen?
23.5%
What is the low alarm level for the Mine Rescue’s MX6 Monitor for Methane?
1.0%
What is the high alarm level for the Mine Rescue’s MX6 Monitor for Methane?
2.0%